S12700 V200R013C00 Log Reference

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NSADP

NSADP

NSADP/4/NS_ID_RPCFAIL

Message

NSADP/4/NS_ID_RPCFAIL: Failed to send message to slot [ULONG1]. (MessageType=[ULONG2], ErrorCode=[ULONG3])

Description

After the transmission of RPC/IPC messages failed, the NetStream module records the slot ID, message type, and error code.

Parameters

Parameter Name Parameter Meaning
ULONG1 Indicates the slot ID.
MessageType Indicates message type.
ErrorCode Indicates the error code.

Possible Causes

RPC or IPC communication failed.

Procedure

  1. Collect log information and configuration information, and then contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.

NSADP/4/NS_ID_CREATEFAIL

Message

NSADP/4/NS_ID_CREATEFAIL: Netstream Fails to create streams in slot [slot-id]. (FailedInputStreamCount=[STRING], FailedOutputStreamCount=[STRING])

Description

NetStream flows failed to be created.

Parameters

Parameter Name Parameter Meaning
slot-id Indicates the slot ID.
FailedInputStreamCount Indicates the number of inbound NetStream flows that failed to be created.
FailedOutputStreamCount Indicates the number of outbound NetStream flows that failed to be created.

Possible Causes

The number of NetStream flows received the maximum that can be created. As a result, NetStream flows failed to be created.

Procedure

  1. Run the display netstream all command to check the NetStream configuration on a device. If ip netstream inbound or ip netstream outbound exists on an interface, the NetStream configuration has been configured on this interface.
  2. On the interface that has the NetStream function configured, run the ip netstream sampler fix-packets packet-interval { inbound | outbound } command to increase the NetStream sampling rate. Check whether the device still prints this log.

    • If so, go to step 3.
    • If not, no further action is required.

  3. Collect log information and configuration information, and then contact technical support personnel. You can collect diagnostic information using the display diagnostic-information command.

NSADP/4/NS_NOT_SP_ACTIVETIME

Message

NSADP/4/NS_NOT_SP_ACTIVETIME: Slot [STRING] does not support the command of NetStream active aging time.

Description

The board does not support the command that configures the active aging time.

Parameters

Parameter Name Parameter Meaning
Slot Indicates the slot ID of a board.

Possible Causes

When you configure the active aging time, the system prompts that the board does not support the command.

Procedure

  1. This log message indicates a normal situation, and no action is required.