S12700 V200R013C00 Log Reference

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ASMNG

ASMNG

ASMNG/3/CONFIRM_AS_FAIL

Message

ASMNG/3/CONFIRM_AS_FAIL: Failed to confirm AS. (AS MAC=[STRING])

Description

Failed to confirm the AS.

Parameters

Parameter Name Parameter Meaning
AS MAC Indicates the AS's MAC address.

Possible Causes

  • Cause 1: Failed to check the record of the authenticated AS.
  • Cause 2: Failed to add the AS's MAC address to the whitelist.

Procedure

  1. Run the display as command to check whether the AS's MAC address in the command output is consistent with the actual one.
    • If so, go to step 2.
    • If not, run the confirm command to confirm the AS allowed to pass authentication. If the fault persists, go to step 2.
  2. A flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  3. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/CREATE_SLOT_FAIL

Message

ASMNG/3/CREATE_SLOT_FAIL: Failed to create slot on AS. (AS Name=[STRING], Slot ID=[INTEGER])

Description

A slot failed to be created on the AS.

Parameters

Parameter Name Parameter Meaning
AS Name Indicates the AS name.
Slot ID Indicates a slot ID.

Possible Causes

Failed to create a slot on the AS using the slot command.

Procedure

  1. Run the slot command again to create a slot on the AS.
  2. If the fault persists, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/DEL_AS_FAIL

Message

ASMNG/3/DEL_AS_FAIL: Failed to delete AS. (AS Name=[STRING])

Description

The AS failed to be deleted.

Parameters

Parameter Name Parameter Meaning
AS Name Indicates the AS name.

Possible Causes

The AS failed to be deleted.

Procedure

  1. According to the error information displayed during the operation, delete other configurations of the AS, such as the fabric port binding configuration and template configuration.
  2. Run the undo as name command to delete the AS.
  3. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  4. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/DEL_SLOT_FAIL

Message

ASMNG/3/DEL_SLOT_FAIL: Failed to delete slot on AS. (AS Name=[STRING], Slot ID=[INTEGER])

Description

The slot on the AS failed to be deleted.

Parameters

Parameter Name Parameter Meaning
AS Name Indicates the AS name.
Slot ID Indicates a slot ID.

Possible Causes

The slot on the AS failed to be deleted.

Procedure

  1. According to the error information displayed during the operation, delete other configurations of the AS, such as the fabric port binding configuration and template configuration.
  2. Run the undo slot command to delete the slot on the AS.
  3. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  4. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/READ_ASINDEX_FAIL

Message

ASMNG/3/READ_ASINDEX_FAIL: Failed to read the AS index.

Description

The AS failed to read the index number from the flash memory.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The AS failed to read the index number from the flash memory.

Procedure

  1. Run the undo uni-mng command to delete the SVF configuration.
  2. Reconfigure SVF.
  3. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  4. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/READ_MANMAC_FAIL

Message

ASMNG/3/READ_MANMAC_FAIL: Failed to read the management MAC.

Description

The AS failed to read the management MAC address from the flash memory.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The AS failed to read the management MAC address from the flash memory.

Procedure

  1. Enable the AS to read the management MAC address from the flash memory again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  2. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  3. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/READ_PSK_FAIL

Message

ASMNG/3/READ_PSK_FAIL: Failed to read the pre-shared key.

Description

The AS failed to read the pre-shared key from the flash memory.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

Failed to obtain the DTLS pre-shared key from the flash memory.

Procedure

  1. Enable the AS to read the pre-shared key from the flash memory again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  2. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  3. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/REPLACE_SLOT_FAIL

Message

ASMNG/3/REPLACE_SLOT_FAIL: Failed to replace slot on AS. (AS Name=[STRING], Slot ID=[INTEGER])

Description

The slot on the AS failed to be replaced.

Parameters

Parameter Name Parameter Meaning
AS Name Indicates the AS name.
Slot ID Indicates a slot ID.

Possible Causes

Failed to run the slot slot-id1 replace-model model-name or slot slot-id2 [ to slot-id3 ] [ replace-model model-name ] command replace the slot on the AS.

Procedure

  1. Run the display as command to check whether the AS is online.
    • If so, go to step 2.
    • If not, go to step 4.
  2. Run the display uni-mng interface fabric-port state command to check the Local-port connected to this AS.
  3. In the stack port view, run the shutdown interface command to shut down this port.
  4. Run the display this command in the AS view to check whether this AS has other configurations, such as the fabric port binding configuration and template configuration. If so, delete these configurations.
  5. Run the slot command in the AS view to replace the slot on the AS again.
  6. If the fault persists, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/RESET_AS_FAIL

Message

ASMNG/3/RESET_AS_FAIL: Failed to reset AS. (AS Name=[STRING])

Description

The AS failed to be restarted.

Parameters

Parameter Name Parameter Meaning
AS Name Indicates the AS name.

Possible Causes

The AS failed to be restarted.

Procedure

  1. Restart the AS again. For details about restarting an AS, see "Restarting an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  2. Run the display as command to check whether this AS is online.
    • If so, the AS is restarted successfully.
    • If not, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/SAVE_ASINDEX_FAIL

Message

ASMNG/3/SAVE_ASINDEX_FAIL: Failed to save the AS index.

Description

The AS failed to save the AS index to the flash memory.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The AS failed to save the AS index to the flash memory.

Procedure

  1. Run the undo uni-mng command to delete the SVF configuration.
  2. Reconfigure SVF.
  3. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  4. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/SAVE_MANMAC_FAIL

Message

ASMNG/3/SAVE_MANMAC_FAIL: Failed to save the management MAC.

Description

The AS failed to save the management MAC address to the flash memory.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The AS failed to save the management MAC address to the flash memory.

Procedure

  1. Enable the AS to save the management MAC address to the flash memory again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  2. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  3. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/SAVE_PSK_FAIL

Message

ASMNG/3/SAVE_PSK_FAIL: Failed to save the pre-shared key.

Description

The AS failed to save the pre-shared key to the flash memory.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The AS failed to save the pre-shared key to the flash memory.

Procedure

  1. Enable the AS to save the pre-shared key to the flash memory again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  2. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  3. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/SEND_MANMAC_FAIL

Message

ASMNG/3/SEND_MANMAC_FAIL: Failed to send the management MAC to other board. (Slot ID=[INTEGER])

Description

The AS failed to send the management MAC address to another slot.

Parameters

Parameter Name Parameter Meaning
Slot ID Indicates a slot ID.

Possible Causes

The AS failed to send the management MAC address to another slot.

Procedure

  1. Enable the AS to send the management MAC address to another slot again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  2. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  3. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.

ASMNG/3/SEND_PSK_FAIL

Message

ASMNG/3/SEND_PSK_FAIL: Failed to send the pre-shared key to other board. (Slot ID=[INTEGER])

Description

The AS failed to send the pre-shared key to another slot.

Parameters

Parameter Name Parameter Meaning
Slot ID Indicates a slot ID.

Possible Causes

The AS failed to send the pre-shared key to another slot.

Procedure

  1. Enable the AS to send the pre-shared key to another slot again after this AS is restarted. For details about restarting an AS, see "Restarting an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  2. If the fault persists, a flash failure occurred. Replace this AS. For details, see "Replacing an AS" in the S12700 V200R013C00 Configuration Guide - Device Management Configuration - SVF Configuration.
  3. If the fault persists after this AS is replaced, collect log information and configuration information, and then contact technical support personnel.You can collect diagnostic information using the display diagnostic-information command.