S12700 V200R013C00 Log Reference

This document provides the explanations, causes, and recommended actions of logs on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
OAM

OAM

OAM/4/BOARD_OUT_TUNN

Message

OAM/4/BOARD_OUT_TUNN:[TunnelName] had been removed but not deleted in OAM table!

Description

The tunnel interface was pulled out, but the tunnel was not deleted.

Parameters

Parameter Name Parameter Meaning
TunnelName indicates the tunnel name.

Possible Causes

The Tunnel interface board that was detected by OAM was pulled out.

Procedure

  1. This log message is informational only, and no action is required.

OAM/4/LSP_EN_AVA

Message

OAM/4/LSP_EN_AVA:LSP enter available state. (Ingress LsrId=[STRING], Tunnel SessionId=[ULONG])

Description

The LSP entered the available state.

Parameters

Parameter Name Parameter Meaning
Ingress LsrId indicates the LSR ID on the ingress.
Tunnel SessionId indicates the tunnel ID.

Possible Causes

The LSP entered the available state.

Procedure

  1. This log message indicates a normal situation, and no action is required.

OAM/3/LSP_EN_DEF

Message

OAM/3/LSP_EN_DEF:LSP enter defect state! (Ingress LsrId=[STRING], Tunnel SessionId=[ULONG])

Description

The LSP entered the defect state.

Parameters

Parameter Name Parameter Meaning
Ingress LsrId indicates the LSR ID on the ingress.
Tunnel SessionId indicates the tunnel ID.

Possible Causes

The LSP entered the defect state, or the OAM configuration was incorrect.

Procedure

  1. Check whether the OAM configuration is correct.
  2. If the OAM configuration is incorrect, reconfigure OAM.
  3. Check whether the current network is normal.

OAM/3/LSP_EN_UNAVA

Message

OAM/3/LSP_EN_UNAVA:LSP enter unavailable state! (Ingress LsrId=[STRING], Tunnel SessionId=[ULONG])

Description

The LSP entered the unavailable state.

Parameters

Parameter Name Parameter Meaning
Ingress LsrId indicates the LSR ID on the ingress.
Tunnel SessionId indicates the tunnel ID.

Possible Causes

The LSP entered the unavailable state, or the OAM configuration was incorrect.

Procedure

  1. Check whether the OAM configuration is correct.
  2. If the OAM configuration is incorrect, reconfigure OAM.
  3. Check whether the current network is normal.

OAM/4/LSP_QUIT_DEF

Message

OAM/4/LSP_QUIT_DEF:LSP quit defect state. (Ingress LsrId=[STRING], Tunnel SessionId=[ULONG])

Description

The LSP quitted the defect state.

Parameters

Parameter Name Parameter Meaning
Ingress LsrId indicates the LSR ID on the ingress.
Tunnel SessionId indicates the tunnel ID.

Possible Causes

The LSP quitted the defect state.

Procedure

  1. This log message indicates a normal situation, and no action is required.

OAM/4/LSP_START_DET

Message

OAM/4/LSP_START_DET:LSP start detect. (Ingress LsrId=[STRING], Tunnel SessionId=[ULONG])

Description

Detection on the LSP started.

Parameters

Parameter Name Parameter Meaning
Ingress LsrId indicates the LSR ID on the ingress.
Tunnel SessionId indicates the tunnel ID.

Possible Causes

Detection on the LSP started.

Procedure

  1. This log message indicates a normal situation, and no action is required.

OAM/4/LSP_STOP_DET

Message

OAM/4/LSP_STOP_DET:LSP stop detect. (Ingress LsrId=[STRING], Tunnel SessionId=[ULONG])

Description

Detection on the LSP was stopped.

Parameters

Parameter Name Parameter Meaning
Ingress LsrId indicates the LSR ID on the ingress.
Tunnel SessionId indicates the tunnel ID.

Possible Causes

Detection on the LSP was stopped manually.

Procedure

  1. This log message indicates a normal situation, and no action is required.

OAM/5/NOTIFY_SMOOTH

Message

OAM/5/NOTIFY_SMOOTH:Notify hardware adapter to smooth.

Description

The hardware was notified to perform data smoothing.

Parameters

Parameter Name Parameter Meaning
None None

Possible Causes

The hardware was notified to perform data smoothing.

Procedure

  1. Check whether the active/standby switchover is performed or the slave board is inserted, and view the current status of the system.

OAM/3/PDT_DELETE

Message

OAM/3/PDT_DELETE:Failed to delete the OAM entry. (Index=[ULONG])

Description

Failed to delete the OAM instance.

Parameters

Parameter Name Parameter Meaning

Index

Indicates the index of OAM.

Possible Causes

Failed to delete the OAM instance.

Procedure

  1. Reconfigure OAM. If this log message is no longer displayed, it indicates that the fault is rectified.
  2. Collect log information and configuration information, and then contact technical support personnel.

OAM/3/PDT_FAIL_ADD

Message

OAM/3/PDT_FAIL_ADD:Failed to add the OAM entry. (Index=[ULONG])

Description

The product failed to add the OAM instance.

Parameters

Parameter Name Parameter Meaning

Index

Indicates the index of OAM.

Possible Causes

Failed to add the OAM entry.

Procedure

  1. Reconfigure OAM. If this log message is no longer displayed, it indicates that the fault is rectified.
  2. Collect log information and configuration information, and then contact technical support personnel.

OAM/3/PDT_GET_DETECT_INFO

Message

OAM/3/PDT_GET_DETECT_INFO:Failed to get batch defect result!

Description

Failed to obtain the OAM detection result.

Parameters

Parameter Name Parameter Meaning
None None.

Possible Causes

Failed to obtain the OAM detection result.

Procedure

  1. Reconfigure OAM. If this log message is no longer displayed, it indicates that the fault is rectified.
  2. Collect log information and configuration information, and then contact technical support personnel.

OAM/3/PDT_SLT

Message

OAM/3/PDT_SLT:Failed to select another board when selected IO board was plugged out!

Description

Failed to re-select the board when the interface board was pulled out.

Parameters

Parameter Name Parameter Meaning
None None.

Possible Causes

Failed to select the board.

Procedure

  1. Check whether another LPU is available on the device. If no LPU is installed on the device, install an LPU.
  2. Collect log information and configuration information, and then contact technical support personnel.

OAM/3/PDTMSG_ERR

Message

OAM/3/PDTMSG_ERR:The type of message received is wrong! (Type=[ULONG])

Description

The type of the message was incorrect.

Parameters

Parameter Name Parameter Meaning
Type Indicates the message type.

Possible Causes

The type of message reported by the hardware adaptation was incorrect.

Procedure

  1. Collect log information and configuration information, and then contact technical support personnel.

OAM/4/SLSP_EN_AVA

Message

OAM/4/SLSP_EN_AVA:Static LSP (Name=[STRING]) enter available state.

Description

The static LSP entered the available state.

Parameters

Parameter Name Parameter Meaning
Name Indicates the name of an LSP.

Possible Causes

The static LSP entered the available state.

Procedure

  1. This log message is informational only, and no action is required.

OAM/3/SLSP_EN_DEF

Message

OAM/3/SLSP_EN_DEF:Static LSP (Name=[STRING]) enter defect state!

Description

The static LSP entered the defect state.

Parameters

Parameter Name Parameter Meaning
Name Indicates the name of an LSP.

Possible Causes

The LSP entered the defect state or the user configuration was incorrect.

Procedure

  1. Check whether the OAM configuration was correct. If not, try to restore the OAM configuration manually.
  2. Check whether the network is normal. If not, try to rectify the fault of the network.

OAM/3/SLSP_EN_UNAVA

Message

OAM/3/SLSP_EN_UNAVA:Static LSP (Name=[STRING]) enter unavailable state.

Description

The static LSP entered the unavailable state.

Parameters

Parameter Name Parameter Meaning
Name Indicates the name of an LSP.

Possible Causes

The LSP entered unavailable state or the configuration command was incorrect.

Procedure

  1. Check whether the OAM configuration was correct. If not, try to restore the OAM configuration manually.
  2. Check whether the network is normal. If not, try to rectify the fault of the network.

OAM/4/SLSP_QUIT_DEF

Message

OAM/4/SLSP_QUIT_DEF:Static LSP (Name=[STRING]) quit defect state.

Description

The static LSP left the defect state.

Parameters

Parameter Name Parameter Meaning
Name Indicates the name of an LSP.

Possible Causes

The static LSP left the defect state.

Procedure

  1. This log message is informational only, and no action is required.

OAM/4/SLSP_START_DET

Message

OAM/4/SLSP_START_DET:Static LSP start detect. (InLabel=[ULONG])

Description

Detection of the static LSP started.

Parameters

Parameter Name Parameter Meaning
InLabel Indicates the incoming label.

Possible Causes

Detection of the static LSP started.

Procedure

  1. This log message is informational only, and no action is required.

OAM/4/SLSP_STOP_DET

Message

OAM/4/SLSP_STOP_DET:Static LSP stop detect. (InLabel=[ULONG])

Description

Detection of the static LSP was stopped.

Parameters

Parameter Name Parameter Meaning
InLabel Indicates the incoming label.

Possible Causes

Detection of the static LSP was stopped.

Procedure

  1. This log message is informational only, and no action is required.

OAM/4/TUN_EN_AVA

Message

OAM/4/TUN_EN_AVA:[TunnelName] enter available state.

Description

The LSP entered the available state.

Parameters

Parameter Name Parameter Meaning

TunnelName

Indicates the tunnel name.

Possible Causes

The LSP entered the available state.

Procedure

  1. This log message is informational only, and no action is required.

OAM/3/TUN_EN_DEF

Message

OAM/3/TUN_EN_DEF:[TunnelName] enter defect state.

Description

OAM entered the defect state.

Parameters

Parameter Name Parameter Meaning

TunnelName

Indicates the name of a tunnel.

Possible Causes

The LSP entered the defect state or the user configuration was incorrect.

Procedure

  1. Check whether the OAM configuration was correct.
  2. If the OAM configuration was incorrect, try to restore OAM configuration manually.
  3. Check whether the network is normal. If not, try to rectify the fault of the network.

OAM/3/TUN_EN_UNAVA

Message

OAM/3/TUN_EN_UNAVA:[TunnelName] enter unavailable state.

Description

The LSP entered the unavailable state.

Parameters

Parameter Name Parameter Meaning

TunnelName

Indicates the tunnel name.

Possible Causes

The LSP entered the unavailable state.

Procedure

  1. Check whether the OAM configuration is correct. If not, try to restore the OAM configuration manually.
  2. Check whether the current network is normal.

OAM/4/TUN_QUIT_DEF

Message

OAM/4/TUN_QUIT_DEF:[TunnelName] quit defect state.

Description

OAM left the defect state.

Parameters

Parameter Name Parameter Meaning

TunnelName

indicates the name of a tunnel

Possible Causes

OAM left the defect state.

Procedure

  1. This log message is informational only, and no action is required.

OAM/4/TUN_START_DET

Message

OAM/4/TUN_START_DET:[TunnelName] start detect.

Description

OAM detection started.

Parameters

Parameter Name Parameter Meaning

TunnelName

Indicates the tunnel name.

Possible Causes

OAM detection started.

Procedure

  1. This log message is informational only, and no action is required.

OAM/4/TUN_STOP_DET

Message

OAM/4/TUN_STOP_DET:[TunnelName] stop detect.

Description

OAM detection was stopped.

Parameters

Parameter Name Parameter Meaning

TunnelName

Indicates the tunnel name.

Possible Causes

OAM detection was stopped manually.

Procedure

  1. This log message is informational only, and no action is required.

OAM/3/UPDATA_PDT_FAIL

Message

OAM/3/UPDATA_PDT_FAIL:Failed to update the hardware adapter information on io board!

Description

Failed to update the software adaptation information.

Parameters

Parameter Name Parameter Meaning

None

None.

Possible Causes

Information about the hardware adaptation of an LPU failed to be updated.

Procedure

  1. Reconfigure OAM. If this log message is no longer displayed, it indicates that the fault is rectified.
  2. Collect log information and configuration information, and then contact technical support personnel.