Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HUAWEI-ENERGYMNGT-MIB

HUAWEI-ENERGYMNGT-MIB

Function Overview

HUAWEI-ENERGYMNGT-MIB is used for power management and power consumption query. The MIB enables query and configuration of device power, power statistics cycle, average power, rated power, current power, power threshold, and energy-conservation mode.

Root directory: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).huawei(2011).huaweiUtility(6).hwEnergyMngt(157)

Relationship Between Tables

None.

Description of Single Objects

hwPowerConsumption

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.1.1

hwPowerConsumption

Counter64

Read-only

This object indicates the total power consumption of the device.

This object is implemented as defined in the corresponding MIB file.

hwPowerStatPeriod

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.1.2

hwPowerStatPeriod

Enumeration

Read-write

This object indicates the interval for collecting power consumption information. The values are:

1: fifteenMinutes(1)

2: thirtyMinutes(2)

3: oneHour(3)

4: oneDay(4)

5: oneWeek(5)

6: oneMonth(6)

Default: 3: oneHour(3)

This object is implemented as defined in the corresponding MIB file.

hwAveragePower

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.1.3

hwAveragePower

Integer32

Read-only

This object indicates the average power of the device.

This object is implemented as defined in the corresponding MIB file.

hwRatedPower

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.1.4

hwRatedPower

Integer32

Read-only

This object indicates the rated power.

This object is implemented as defined in the corresponding MIB file.

hwThresholdOfPower

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.1.5

hwThresholdOfPower

Integer32

Read-write

Currently, the maximum access is read-only.

This object indicates the power threshold.

This object is implemented as defined in the corresponding MIB file.

hwCurrentPower

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.1.6

hwCurrentPower

Integer32

Read-only

This object indicates the current power.

This object is implemented as defined in the corresponding MIB file.

hwEnergySavingMode

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.3.1

hwEnergySavingMode

Enumeration

Read-write

This object indicates the energy-conservation mode, including:

1: userDefined(1), this mode is not supported now

2: standard(2)

3: basic(3)

4: deep(4)

This object is implemented as defined in the corresponding MIB file.

Description of MIB Tables

hwBoardPowerMngtTable

This table is used to query board power.

The index of this table is hwBoardIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.2.1.1.1

hwBoardIndex

Integer32

Read-only

This object indicates the board index.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.157.2.1.1.2

hwBoardType

DisplayString

Read-only

This object indicates the board type.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.157.2.1.1.3

hwBoardName

DisplayString

Read-only

This object indicates the board name.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.157.2.1.1.5

hwBoardRatedPower

Integer32

Read-only

This object indicates the rated power of the board.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.157.2.1.1.6

hwBoardThresholdOfPower

Integer32

Read-write

Currently, the maximum access is read-only.

This object indicates the power threshold.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

hwEnergySavingParameterTable

This table describes the energy-saving mode variable table.

The index of this table is hwEnergySavingParameterIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.3.3.1

hwEnergySavingParameterIndex

Integer32

read-only

This object indicates the energy-saving mode index.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.157.3.3.2

hwEnergySavingParameterValue

DisplayString

read-write

This object indicates the energy-saving mode variable value.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

No entry can be created in this table.

Modification Restriction

hwEnergySavingParameterValue can be modified.

Deletion Restriction

No entry in this table can be deleted.

Access Restriction

The entries in this table can be read without restriction.

hwEnergySavingCapabilityMngtTable

This table queries energy-conservation information.

The index of this table is hwEnergySavingCapabilityDescIndex.

OID

Object Name

Syntax

Max Access

Description

Implemented Specifications

1.3.6.1.4.1.2011.6.157.3.4.1

hwEnergySavingCapabilityDescIndex

Integer32

Read-only

This object indicates the index of energy-conservation capability description.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.157.3.4.2

hwEnergySavingCapabilityDescLanguage

Integer32

Read-only

This object indicates the text of energy-conservation capability.

This object is implemented as defined in the corresponding MIB file.

1.3.6.1.4.1.2011.6.157.3.4.3

hwEnergySavingCapabilityDesc

Integer32

Read-only

This object indicates the description of energy-conservation capability.

This object is implemented as defined in the corresponding MIB file.

Creation Restriction

No entry can be created in this table.

Modification Restriction

The entries in this table cannot be modified.

Deletion Restriction

The entries in this table cannot be deleted.

Access Restriction

The entries in this table can be read without restriction.

Description of Alarm Objects

None.

Objects Not Supported by the Device

The functions of the following objects are not supported on the device. Therefore, do not use these objects to maintain the device.

Table 40-1  List of objects not supported by the device

Object OID

Object Name

Table to Which the Object Belongs

1.3.6.1.4.1.2011.6.157.2.1.1.4

hwBoardCurrentPower

hwBoardPowerMngtTable

1.3.6.1.4.1.2011.6.157.3.2.1.1 hwEnergySavingMethodIndex hwEnergySavingMethodTable
1.3.6.1.4.1.2011.6.157.3.2.1.2 hwEnergySavingMethodEnable hwEnergySavingMethodTable