S2720, S5700, and S6720 V200R013C00

This document describes the configurations of Device Management, including device status query, hardware management, Stack, SVF, cloud-based management, PoE, monitoring interface, OPS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring 1588v2 on a BC

Configuring 1588v2 on a BC

BC Deployment

As shown in Figure 14-15, NodeBs need to synchronize clocks with an external clock source. All devices on the bearer network support 1588v2. Each device on the bearer network receives clock signals from an upstream device and sends clock signals to a downstream device. In this manner, NodeBs can synchronize clocks with the external clock source. Devices are configured as BC nodes to connect to the external clock source, synchronize with the external clock source, and send clock information to other devices on the bearer network. Other backbone nodes on the bearer network are deployed as BCs, which can synchronize with the external clock source and send clock information to downstream devices.

Figure 14-15  Configuring 1588v2 on a BC

Pre-configuration Tasks

Before configuring 1588v2 on a BC, complete the following tasks:

  • Set link layer protocol parameters for interfaces to ensure that the link layer protocol status of the interfaces is Up.

  • Ensure that the BC obtains the clock signal and time signal from the external clock source.

  • Configure synchronous Ethernet to synchronize the clock frequency on the network.

Configuration Procedure

The procedure of configuring 1588v2 on a BC is as follows.