Configuration Guide - Device Management

S2720, S5700, and S6720 V200R013C00

This document describes the configurations of Device Management, including device status query, hardware management, Stack, SVF, cloud-based management, PoE, monitoring interface, OPS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Enabling the Stack Port Error-Down Function

Enabling the Stack Port Error-Down Function

Context

In a stack system, if a stack port continuously receives CRC error packets or flaps between Up and Down states, the corresponding stack link cannot forward traffic normally, thereby affecting network services. The stack port error-down function can shut down a stack port and switch traffic to other stack links if the rate of received CRC error packets or the number of Up/Down transitions on the stack port reaches the specified threshold. This reduces the impact of a stack port error-down event on network services. Additionally, the system generates stack port error-down alarms to help in fault location.

When one end is a stack port and the other end is a service port, the system does not set the stack port to error-down state or generate an error-down alarm even if this stack port continuously receives CRC error packets.

Procedure

  1. Run the stack port { crc | link-flap } trigger error-down command to enable the stack port error-down function.

    By default, the stack port error-down function is enabled.

  2. Set stack port error-down parameters.

    • Run the stack port { crc | link-flap } trigger { threshold threshold | interval interval } * command to set the stack port error-down alarm threshold and check interval.

      By default, the stack port error-down alarm threshold is 10 times per minute, and the check interval is 3 minutes. That is, the system will set a stack port to error-down state and generate an error-down alarm in the following condition: The stack port receives 10 CRC error packets per minute or alternates between Up and Down states 10 times per minute, and this condition lasts for 3 minutes.

    • Run the stack port { crc | link-flap } trigger error-down auto-recovery-interval auto-recovery-interval command to set the stack port error-down alarm clearance interval.

      By default, the alarm clearance interval is 0, which means that a stack port error-down alarm will not be cleared automatically after it is printed.

Verifying the Configuration

  • Run the display current-configuration | include stack command to view the stack port error-down function configuration.