No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Network Management and Monitoring

S2720, S5700, and S6720 V200R013C00

This document describes the configurations of Network Management and Monitoring, including SNMP, RMON, RMON2, LLDP, Performance Management, iPCA, NQA, Service Diagnosis, Mirroring, Packet Capture, NetStream, sFlow, TWAMP Light, NETCONF, ECA, Intelligent Video O&M, eMDI, and Network Deception.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking NQA Test Results

Checking NQA Test Results

Prerequisites

An NQA test instance has been configured and the NQA test has been completed.

NOTE:
  • If the display command is executed in the NQA view with no test instance name specified, only the test results of the current instance are displayed. If the display command is executed in the system or other views other than the NQA view with no test instance view specified, test results of all test instances are displayed. If a test instance is specified, only the test result of this test instance is displayed.
  • The display nqa results command displays the test results of only the test instances that have been completed.
  • Failed UDP Jitter tests are not recorded in the historical records.
  • If the following conditions are met for an ICMP test instance, the Completion field in the test results will be displayed as no result:
    • The CPU usage exceeds 90% and the configured timeout period is shorter than 6s.
    • Configured frequency ≤ (probe-count - 1) x interval + 6.

      The frequency is configured by the frequency command; the probe-count is configured by the probe-count command; the interval is configured by the interval command.

Procedure

  • Run the display nqa results [ test-instance admin-name test-name ] command to check NQA test results.
  • Run the display nqa history [ test-instance admin-name test-name ] command to check the historical records of NQA test instances.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100065680

Views: 52443

Downloads: 500

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next