Configuration Guide - Reliability

S2720, S5700, and S6720 V200R013C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Summary of CFM Configuration Tasks

Summary of CFM Configuration Tasks

After basic CFM functions are configured, CFM can work properly. To deploy special CFM functions such as loopback, linktrace, adjusting CFM parameters, and CFM association, perform the configurations according to the following sections.

Table 8-8 describes the CFM configuration tasks.

Table 8-8  CFM configuration tasks

Scenario

Description

Task

Configure basic CFM functions

CFM detects connectivity faults on an end-to-end link.

Configuring Basic Ethernet CFM Functions

Configure loopback

Similar to IP ping, loopback monitors connectivity of a path between a MEP and an RMEP.

Configuring Loopback

Configure linktrace

Linktrace sends test packets and waits for a response to check whether the destination device is reachable.

Configuring Linktrace

Set CFM parameters

By adjusting Ethernet CFM parameters, you can better implement end-to-end connectivity fault detection on the Ethernet.

Setting CFM Parameters

Configure CFM association

CFM can be associated with interfaces and detection protocols to quickly report link faults, ensuring service reliability.

Configuring CFM Association