No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Reliability

S2720, S5700, and S6720 V200R013C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BFD Session Cannot Become Up

BFD Session Cannot Become Up

Common Causes

This fault is commonly caused by one of the following:

  • The link carrying the BFD session is faulty. As a result, BFD packets cannot be exchanged.

  • The BFD session flaps frequently.

Procedure

  1. Run the display current-configuration configuration bfd command to check whether the local and remote discriminators at both ends match.

    • If the local and remote discriminators at both ends match, go to step 2.

    • If the local and remote discriminators at both ends do not match, run the discriminator command to correctly configure local and remote discriminators, and then run the display bfd session all command to check whether the BFD session is Up.
      • If the value of the State field is Up, the BFD session has been established.

      • If the value of the State field is not Up, go to step 2.

  2. Run the display current-configuration configuration bfd command to check whether the BFD detection time is longer than the delay before the BFD session becomes Up.

    Detection time = Received Detect Multi of the remote system x max{Local RMRI, Received DMTI}

    Detect Multi is the local detection multiplier, which is set by using the detect-multiplier command. The Required Min Rx Interval (RMRI) is the minimum interval for receiving BFD packets, which is set by using the min-rx-interval command. The Desired Min Tx Interval (DMTI) is the minimum interval for sending BFD packets, which is set by using the min-tx-interval command.

    The link delay can be obtained using the ping or tracert mechanism.

    If the BFD detection time is shorter than the delay before the BFD session becomes Up, run the detect-multiplier, min-rx-interval, and min-tx-interval commands to increase the BFD detection time to be longer than the delay.

Translation
Download
Updated: 2019-04-04

Document ID: EDOC1100065682

Views: 31014

Downloads: 255

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next