Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting CFM Parameters

Setting CFM Parameters

Context

By adjusting Ethernet CFM parameters, you can better implement end-to-end connectivity fault detection on the Ethernet.

Procedure

  • Setting the RMEP activation time

    1. Run system-view

      The system view is displayed.

    2. Run cfm md md-name

      The MD view is displayed.

    3. Run ma ma-name

      The MA view is displayed.

    4. Run active time time

      The RMEP activation time is configured.

      NOTE:

      IEEE 802.1ag has two versions: IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007. This command can be used only on the device running IEEE Standard 802.1ag-2007. Before setting the RMEP activation time, you must use the cfm version command to set the Ethernet CFM version to IEEE Standard 802.1ag-2007.

  • Setting the anti-jitter time during alarm restoration

    1. Run system-view

      The system view is displayed.

    2. Run cfm md md-name

      The MD view is displayed.

    3. Run ma ma-name

      The MA view is displayed.

    4. Run alarm finish time time

      The anti-jitter time during alarm restoration is configured.

      NOTE:

      IEEE 802.1ag has two versions: IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007. This command can be used only on the device running IEEE Standard 802.1ag-2007. Before setting the anti-jitter time during alarm restoration, you must use the cfm version command to set the Ethernet CFM version to IEEE Standard 802.1ag-2007.

  • Setting the anti-jitter time during alarm generation

    1. Run system-view

      The system view is displayed.

    2. Run cfm md md-name

      The MD view is displayed.

    3. Run ma ma-name

      The MA view is displayed.

    4. Run alarm occur time time

      The anti-jitter time during alarm generation is configured.

      NOTE:

      IEEE 802.1ag has two versions: IEEE 802.1ag Draft 7 and IEEE Standard 802.1ag-2007. This command can be used only on the device running IEEE Standard 802.1ag-2007. Before setting the anti-jitter time during alarm generation, you must use the cfm version command to set the Ethernet CFM version to IEEE Standard 802.1ag-2007.