Configuration Guide - Reliability

S2720, S5700, and S6720 V200R013C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Association Between a BFD Session and an Interface to Trigger the Associated Interface in Down State

Configuring Association Between a BFD Session and an Interface to Trigger the Associated Interface in Down State

Pre-configuration Tasks

Before configuring association between a BFD session and an interface, create a BFD session.

NOTE:

Only the S5720EI, S5720HI, S5730HI, S6720EI, S6720HI, and S6720S-EI support this function.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run oam-mgr

    The OAM management view is displayed.

  3. Run oam-bind ingress bfd-session bfd-session-id trigger if-down egress interface interface-type interface-number

    A BFD session is configured to report faults to an interface.

    By default, a BFD session is not enabled to report faults to an interface.

    When a BFD session detects a fault, the physical status of the interface bound to the BFD session becomes Down.

    NOTE:

    The physical interface associated with BFD cannot be the interface of the BFD link. Otherwise, a link deadlock occurs.