Configuration Guide - Reliability

S2720, S5700, and S6720 V200R013C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Switching IEEE 802.1ag Versions

Switching IEEE 802.1ag Versions

Context

By default, IEEE 802.1ag Standard 802.1ag-2007 is enabled on a device. Perform the following operations on each device where IEEE Draft 7 needs to be used.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run cfm version { draft7 | standard }

    The IEEE 802.1ag version is switched.

    By default, IEEE Standard 802.1ag-2007 is enabled on a device.

    NOTE:

    All the devices in an MA must be enabled with either IEEE 802.1ag Draft 7 or IEEE Standard 802.1ag-2007. Otherwise, these devices cannot exchange CFM packets with each other.