No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Reliability

S2720, S5700, and S6720 V200R013C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Creating a MEP

Creating a MEP

Context

MEPs define a CFM area. CFM supports continuity check (CC), loopback (LB), and linktrace (LT) functions on end-to-end links between MEPs.

MEPs are classified into the local MEP and RMEPs.

MEPs are classified into inward- and outward-facing MEPs based on the MEP direction. Device interfaces at both ends of the direct link must be Layer 2 interfaces and support direct link and end-to-end link.

Perform the following operations on each edge device in an MA.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run cfm md md-name

    The MD view is displayed.

  3. Run ma ma-name

    The MA view is displayed.

  4. Run mep mep-id mep-id interface interface-type interface-number [ pe-vid pe-vid ce-vid ce-vid ] { outward | inward }

    The MEP is created.

Follow-up Procedure

  • To create multiple MEPs in an MA, repeat step 4.

  • To create MEPs in multiple MAs, repeat steps 3 and 4.

NOTE:
Do not configure level-0 MEPs on intermediate devices. To specify the level of a MEP, run the cfm md md-name [ level level ].
Translation
Download
Updated: 2019-04-04

Document ID: EDOC1100065682

Views: 30544

Downloads: 253

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next