Configuration Guide - Device Management

S7700 and S9700 V200R013C00

This document describes the configurations of Device Management, including device status query, hardware management, CSS, SVF, PoE, OPS, OIDS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Software and Hardware Support for S9700 Service Port Clustering

Software and Hardware Support for S9700 Service Port Clustering

Device Model

  • S9706

  • S9712

Software Version

V200R001C01 and later

Service Card Model

NOTE:

For details about service cards, see "Cards" in the Hardware Description of the specific product model.

  • EH1D2X08SED4
  • EH1D2X08SED5
  • EH1D2X12SSA0
  • EH1D2X16SFC0
  • EH1D2X40SFC0
  • EH1D2X32SSC0
  • EH1D2X16SSC2
  • EH1D2L02QFC0
  • EH1D2L08QFC0

Pluggable Modules on Service Ports

  • 1 m, 3 m, 5 m (passive), and 10 m (active) SFP+ cables

  • SFP+ optical module and fiber

  • 3 m and 10 m SFP+ AOC cables

NOTE:

The EH1D2X12SSA0 does not support 3 m and 5 m SFP+ high-speed cables.

  • 1 m, 3 m, and 5 m QSFP+ high-speed cables
  • QSFP+ optical module (except the QSFP-40G-SR-BD model) and fiber
  • 10 m QSFP+ AOC cable (supported since V200R009C00)

Usage Constraints

  • On the EH1D2X08SED4 and EH1D2X08SED5 LPUs, at most four ports can be configured as CSS physical member ports. The four physical member ports must be the first four ports (numbered 0 to 3) or the last four ports (numbered 4 to 7) on the LPUs.

  • On the EH1D2X16SFC0, EH1D2X40SFC0, EH1D2X32SSC0 and EH1D2X16SSC2 LPUs, four contiguous ports must be configured as a group of physical member ports together. The port numbers of the four ports must start with 4xN and end with 4xN+3 (N = 0, 1, 2...). For example, ports 0 to 3 or ports 4 to 7 must be configured together, but ports 2 to 5 cannot be configured together. If any port in a group is configured as a physical member port, the other three ports of the same group must also be configured as physical member ports.

The interconnected CSS physical member ports on the two member switches must be both 40GE ports. XGE ports derived from a 40GE port cannot be added to a logical CSS port.

Hardware Configuration

  • Only two S9706 switches, two S9712 switches, or one S9706 and one S9712 can set up a CSS.
  • MPUs in one chassis must be the same model. MPUs in the local and peer chassis can be different models but are recommended to be the same model.

  • Each chassis can have at most two LPUs for CSS connection. It is recommended that you use the same type of LPUs in a chassis for CSS connection. The two chassis must use the same type of ports for CSS connection, for example, 10GE SFP+ optical ports.

  • Each LPU allows only one logical CSS port. Each logical CSS port supports a maximum of 32 physical member ports.

  • Some ports on an LPU can function as CSS ports, while other ports on the LPU function as service ports.