Configuration Guide - Device Management

S7700 and S9700 V200R013C00

This document describes the configurations of Device Management, including device status query, hardware management, CSS, SVF, PoE, OPS, OIDS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking OIDS Monitoring Information

Checking OIDS Monitoring Information

Context

OIDS monitoring information provides insight into the switch running status. For example, this information enables you to learn about diagnosis object attribute data, abnormal attributes, and KPI information.

Procedure

  • Run the display oids monitor current-fault [ type type-name [ { object-index object-index | object-name object-name } [ { attribute-index attribute-index | attribute-name attribute-name } ] ] ] [ slot slot-id ] command to check OIDS monitoring information that triggers abnormal events at the current time. When the OIDS monitoring function is disabled, the display oids monitor current-fault command displays the OIDS monitoring information that triggers abnormal events and is recorded before the OIDS monitoring function is disabled.
  • Run the display oids monitor kpi { data | graph } type type-name { object-index object-index | object-name object-name } { attribute-index attribute-index | attribute-name attribute-name } slot slot-id [ period { 60min | 24h | 72h } { before | after } date-time time date ] command to check KPI information generated within a certain period.
  • Run the display oids monitor status [ type type-name [ { object-index object-index | object-name object-name } [ { attribute-index attribute-index | attribute-name attribute-name } ] ] ] [ slot slot-id ] command to check OIDS monitoring information at the current time.
  • Run the display oids register-status [ type type-name ] [ slot slot-id ] command to check OIDS monitoring and diagnosis item information registered on the switch.