No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Device Management

S7700 and S9700 V200R013C00

This document describes the configurations of Device Management, including device status query, hardware management, CSS, SVF, PoE, OPS, OIDS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Example for Configuring Clock Synchronization Through Multicast MAC-Encapsulated PTP Messages in Delay Mechanism

Example for Configuring Clock Synchronization Through Multicast MAC-Encapsulated PTP Messages in Delay Mechanism

Networking Requirements

As shown in Figure 14-19, devices on the bearer network work at Layer 2. PE1 and PE2 are core devices on the bearer network, and CE1 and CE2 are edge devices on the wireless access network. PE1 and PE2 function as BCs and connect to external BITS clock sources to send frequency signals and clock signals to CE1 and CE2. CE1 and CE2 function as BCs to synchronize with BITS clock signals through PTP and transmit the clock signals in PTP messages to connected NodeBs. NodeB2 does not support PTP but can obtain frequency information through E1 signals to synchronize with the frequency of CE2.

Configure PTP on the bearer network to implement frequency synchronization between NodeBs and bearer network devices. This configuration allows PTP-supporting NodeBs to synchronize with bearer network devices.

Figure 14-19  Networking diagram of configuring clock synchronization through multicast MAC-encapsulated PTP messages

Configuration Roadmap

The configuration roadmap is as follows:

  1. Configure PE1 and PE2 to receive BITS clock signals through BITS interfaces.
  2. Configure the type of devices on the bearer network as BC.

  3. Configure PE1 and PE2 as system master clocks and connect them to BITS clocks. PE1 and PE2 back up each other.

  4. Configure multicast MAC encapsulation for PTP messages and set the delay measurement mechanism to delay because MAC addresses of interfaces are unknown and devices work at Layer 2.

Procedure

  1. Configure PE1 and PE2 to receive BITS clock signals through BITS interfaces.

    For configuration details, see Example for Configuring the BITS as the Master Clock Source of PTP.

  2. Configure PE1 and PE2 as BCs.

    # Enable PTP globally on PE1 and configure PE1 as a BC.

    <HUAWEI> system-view
    [HUAWEI] sysname PE1
    [PE1] ptp enable
    [PE1] ptp device-type bc
    

  3. Enable PTP frequency synchronization on PE1.

    [PE1] clock source ptp synchronization enable
    

  4. Configure PTP on GigabitEthernet1/0/0 and GigabitEthernet1/0/1 of PE1.

    [PE1] interface gigabitethernet 1/0/0
    [PE1-GigabitEthernet1/0/0] ptp delay-mechanism delay
    [PE1-GigabitEthernet1/0/0] ptp enable
    [PE1-GigabitEthernet1/0/0] quit
    [PE1] interface gigabitethernet 1/0/1
    [PE1-GigabitEthernet1/0/1] ptp delay-mechanism delay
    [PE1-GigabitEthernet1/0/1] ptp enable
    [PE1-GigabitEthernet1/0/1] quit
    [PE1] quit

  5. Configure PE2, CE1, and CE2 according to the configuration of PE1.
  6. Verify the configuration.

    # CE1 and CE2 can trace the frequency and time signals of PE1 and PE2. If you run the display ptp all command on CE1, for example, you can view the PTP synchronization status of CE1.

    <CE1> display ptp all
     Device config info
      ------------------------------------------------------------------
      PTP state         :enabled    Domain  value      :0
      Slave only        :no         Device type        :BC
      Static BMC        :no         Local clock ID     :00e0fcfffe171112
      PTP freq-sync     :yes        Time lock success  :yes                         
      PTP acl           :no                                                         
    
      BMC run info
      ------------------------------------------------------------------
      Grand clock ID    :001882fffe77c2cf
      Receive number    :GigabitEthernet1/0/0
      Parent clock ID   :001882fffe1b1bf4
      Parent portnumber :1024
      Priority1         :128        Priority2          :128
      Step removed      :1          Clock accuracy     :32
      Clock class       :6        Time Source        :32
      UTC Offset        :0          UTC Offset Valid   :False
      Time Scale        :PTP        Time Traceable     :True
      Leap              :None       Frequence Traceable:True
    
      Port info
      Name                  State        Delay-mech Ann-timeout Type Domain
      ------------------------------------------------------------------------
      GigabitEthernet1/0/0  slave        delay      9           BC   0
    
      Clock source info
      Clock Pri1 Pri2 Accuracy Class TimeSrc Signal Switch Direction In-Status
      ------------------------------------------------------------------------
      local 128  128  0x31     187   0xa0     -      -      -         -
      bits0   6    6  0x20     187   0x20     none   off   -/-        abnormal
      bits1   6    6  0x20     187   0x20     none   off   -/-        abnormal
    

Configuration File

  • CE1 configuration file

    #
    sysname CE1
    #
    ptp enable
    ptp device-type bc
    clock source ptp synchronization enable
    #
    interface GigabitEthernet1/0/0
     ptp delay-mechanism delay
     ptp enable
    #
    interface GigabitEthernet1/0/1
     ptp delay-mechanism delay
     ptp enable
    #
    return  
    
  • CE2 configuration file

    #
    sysname CE2
    #
    ptp enable
    ptp device-type bc
    clock source ptp synchronization enable
    #
    interface GigabitEthernet1/0/0
     ptp delay-mechanism delay
     ptp enable
    #
    interface GigabitEthernet1/0/1
     ptp delay-mechanism delay
     ptp enable
    #
    return  
    
  • PE1 configuration file

    #
    sysname PE1
    #
    clock bits-type 1pps-tod in bits0
    #
    ptp enable
    ptp device-type bc
    clock source ptp synchronization enable
    ptp clock-source bits0 on
    #
    interface GigabitEthernet1/0/0
     ptp delay-mechanism delay
     ptp enable
    #
    interface GigabitEthernet1/0/1
     ptp delay-mechanism delay
     ptp enable
    #
    return
    
  • PE2 configuration file

    #
    sysname PE2
    #
    clock bits-type 1pps-tod in bits0
    #
    ptp enable
    ptp device-type bc
    clock source ptp synchronization enable
    ptp clock-source bits0 on
    #
    interface GigabitEthernet1/0/0
     ptp delay-mechanism delay
     ptp enable
    #
    interface GigabitEthernet1/0/1
     ptp delay-mechanism delay
     ptp enable
    #
    return
    