No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Configuration Guide - Device Management

S7700 and S9700 V200R013C00

This document describes the configurations of Device Management, including device status query, hardware management, CSS, SVF, PoE, OPS, OIDS, energy-saving management, information center, fault management, NTP, synchronous ethernet, PTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for Synchronous Ethernet

Licensing Requirements and Limitations for Synchronous Ethernet

Involved Network Elements

BITS clock source

Licensing Requirements

Synchronous Ethernet is not under license control.

Version Requirements

Table 13-1  Products and versions supporting synchronous Ethernet

Series

Product

Software Version

S7700

S7703, S7706, S7712

V200R010C00, V200R011C10, V200R012C00, V200R013C00

This feature is not supported when MCUD is installed.

S7703 PoE

V200R013C00

S7706 PoE

V200R013C00

S9700

S9703, S9706, S9712

V200R001(C00&C01), V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007(C00&C10), V200R008C00, V200R009C00, V200R010C00, V200R011C10, V200R012C00, V200R013C00

NOTE:
For details about software mappings, visit Hardware Query Tool and search for the desired product model.

Feature Limitations

Precautions

  • To use the synchronous Ethernet function, ensure that the CKM-clock daughter card is installed on a switch.
  • When a switch uses the active and standby MPUs and needs to use a clock daughter card, you must install a clock daughter card on both the active and standby MPUs.
  • The synchronous Ethernet function applies only to the EH1D2S24CEA0 and X series boards (excluding the EH1D2G48TX1E, ET1D2G48TX1E, X5E, X5H, X5L, and X5S boards). On the X1E series boards, a switch needs to be configured to work in enhanced mode using the set service-mode command.
  • In a CSS scenario, synchronous Ethernet is not supported.
  • Synchronous Ethernet does not apply to GE electrical interfaces, including GE combo interfaces that work in electrical interface mode.

Clock Sources Supported by Switches

Table 13-2 lists the clock sources supported by switches.

Table 13-2  Supported clock sources

Clock No.

Clock Source Name

Description

0

Inner Clock

Clock signal generated by the internal oscillator of a clock daughter card.

1

BITS0

Clock signal sent or received by the BITS0 interface of the master main control board on the local device.

2

BITS1

Clock signal sent or received by the BITS1 interface of the master main control board on the local device.

3

Slave Board BITS0

Clock signal sent or received by the BITS0 interface of the slave main control board on the local device.

4

Slave Board BITS1

Clock signal sent or received by the BITS1 interface of the slave main control board on the local device.

5

Left Frame Clock

Clock signal sent from the left side of the frame by the LPUs with smaller slot IDs.

  • On the S7703, S7703 PoE, and S9703, LPUs in slot 1 to slot 3 send clock signals from the left side of the frame.
  • On the S7706, S7706 PoE, and S9706, LPUs in slot 1 to slot 3 send clock signals from the left side of the frame.
  • On the S7712 and S9712, LPUs in slot 1 to slot 6 send clock signals from the left side of the frame.

6

Right Frame Clock

Clock signal sent from the right side of the frame by the LPUs with larger slot IDs.

  • On the S7703, S7703 PoE, and S9703, no LPUs reside on the right side of the frame.
  • On the S7706, S7706 PoE, and S9706, LPUs in slot 4 to slot 6 send clock signals from the right side of the frame.
  • On the S7712 and S9712, LPUs in slot 7 to slot 12 send clock signals from the right side of the frame.

7

FSU

Clock source on the flexible service unit (FSU). This clock source is reserved.

8

Slave Board FSU

Clock source on the peer flexible service unit (FSU). This clock source is reserved.

9

System Clock

System clock. A system clock is the clock source automatically selected by a switch based on priorities and SSM quality levels or the clock source manually or forcibly specified.

10

Peer System Clock

System clock of the peer board.

  • The system clock, BITS0 clock, and BITS1 clock are external clocks used to synchronize clock signals. The external clocks can be selected as the master clock source.
  • The three external clocks can function both as a reference clock source of each other and the input of clock signals. Other clocks can function only as a reference clock source of an external clock.
  • A system clock can select any of the clocks with the ID of 0 to 8 as a reference clock source.
  • A BITS clock can select one of the clocks with the ID of 5 to 9 as a reference clock source.
Translation
Download
Updated: 2019-04-20

Document ID: EDOC1100065738

Views: 45229

Downloads: 39

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share