Configuration Guide - MPLS

S7700 and S9700 V200R013C00

This document describes the configurations of MPLS, including Static LSP, MPLS LDP, MPLS QoS, MPLS TE, MPLS OAM, Seamless MPLS.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Blocking Synchronization Between LDP and IS-IS on an Interface

(Optional) Blocking Synchronization Between LDP and IS-IS on an Interface

Context

The ldp-sync enable command run in an IS-IS process enables synchronization between LDP and IS-IS on all local IS-IS interfaces. On an IS-IS interface transmits importance services, LDP and IS-IS synchronization may affect service transmission. If the link is working properly and an LDP session over the link fails, IS-IS sends link state PDUs (LSPs) to advertise the maximum cost of the link. As a result, IS-IS does not select the route for the link, which affects important service transmission.

To prevent the preceding problem, block LDP and IS-IS synchronization on an IS-IS interface that transmits important services.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The IS-IS interface view is displayed.

  3. (Optional) On an Ethernet interface, run undo portswitch

    The interface is switched to Layer 3 mode.

    By default, an Ethernet interface works in Layer 2 mode.

  4. Run isis ldp-sync block

    Synchronization between LDP and IS-IS is blocked on the interface.

    By default, synchronization between LDP and IS-IS is not blocked on an interface.