Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Configuring a Period for an AC Interface to Restore a Blocked Interface

(Optional) Configuring a Period for an AC Interface to Restore a Blocked Interface

Context

After an AC interface enabled with L2VPN loop detection detects a loop, a period can be specified for the AC interface to restore a blocked interface. That is, if a blocked interface does not receive any L2VPN loop detection packet within the period specified by recovery-time, it will be restored to normal state.

If a device is on multiple loops, interfaces on the device may alternate between blocked and normal states during the initial detection stage. To prevent interface status flapping, you are advised to set recovery-time to a larger value.

Perform the following operations on the PE.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The interface view is displayed.

  3. (Optional) On an Ethernet interface, run undo portswitch

    The interface is switched to Layer 3 mode.

    By default, an Ethernet interface works in Layer 2 mode.

  4. Run loop-detect recovery-time recovery-time

    A period is configured for an AC interface to restore a blocked interface.

    By default, an AC interface restores a blocked interface every 15 seconds.