Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RMON

RMON

RMON_1.3.6.1.2.1.16.0.1 risingAlarm

Description

RMON/4/ALARMUP:OID [OID] Alarm table [alarm-table-index] monitors [sample-object-oid] with the sample type being [sample-type], and the sampled alarm value [alarm-value] is greater than or equal to [rising-value].

The value of the alarm entity was higher than uprise.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.2.1.16.0.1 Warning environmentalAlarm(6)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

alarm-table-index

Indicates the index of the alarm entry.

sample-object-oid

Indicates the OID of the sampled object.

sample-type

Indicates the type of the sampled alarm.

alarm value

Indicates the alarm value.

rising-value

Indicates the upper threshold of the alarm.

Impact on the System

None.

Possible Causes

Cause 1:

If the current sampled value was greater than or equal to this threshold, and the last sampled value was less than this threshold, the alarm was generated.

Cause 2:

When this alarm entry became valid, the first sampled value was greater than or equal to this threshold, and alarmStartupAlarm was equal to risingAlarm and risingOrFallingAlarm, the alarm was generated.

Procedure

  • This alarm is triggered only when the upper interface traffic monitoring threshold configured using the rmon alarm command is reached. It is a user-configured monitoring alarm and does not affect services. Therefore, no action is required.

Related Information

None.

RMON_1.3.6.1.2.1.16.0.2 fallingAlarm

Description

RMON/4/ALARMFALL:OID [OID] Alarm table [alarm-table-index] monitors [sample-object-oid] with the sample type being [sample-type], and the sampled alarm value [alarm-value] is less than or equal to [falling-value].

The value of the alarm entity was lower than fallingthreshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.2.1.16.0.2 Warning environmentalAlarm(6)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

alarm-table-index

Indicates the index of the alarm entry.

sample-object-oid

Indicates the OID of the sampled object.

sample-type

Indicates the type of the sampled alarm.

alarm-value

Indicates the alarm value.

falling-value

Indicates the lower threshold of the alarm.

Impact on the System

None.

Possible Causes

Cause 1:

If the current sampled value was less than or equal to this threshold, and the last sampled value was greater than this threshold, the alarm was generated.

Cause 2:

After this alarm entry became valid, when the first sampled value was less than or equal to this threshold, and the values of fallingAlarm, risingAlarm, and risingOrFallingAlarm were equal, the alarm was generated.

Procedure

  • This alarm is triggered only when the lower interface traffic monitoring threshold configured using the rmon alarm command is reached. It is a user-configured monitoring alarm and does not affect services. Therefore, no action is required.

Related Information

None.

RMON_1.3.6.1.4.1.2011.1.3.4.0.1 pririsingAlarm

Description

RMON/3/RISING:OID [OID] Private alarm table [alarm-line-index] monitors [description] with the sample type being [sample-type], and the sampled alarm value [alarm-value] is greater than or equal to [alarm-upper-limit].

The value of the alarm entity was higher than prialarmRisingThreshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.1.3.4.0.1 Minor communicationsAlarm(2)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

alarm-line-index

Indicates the index of the alarm entry.

description

Indicates the description of the alarm entry

sample-type

Indicates the type of the sampled alarm.

alarm-value

Indicates the alarm value.

alarm-upper-limit

Indicates the upper threshold of the alarm.

Impact on the System

None.

Possible Causes

Cause 1:

If the current sampled value was greater than or equal to this threshold, and the last sampled value was less than this threshold, the alarm was generated.

Cause 2:

When this alarm entry became valid, the first sampled value was greater than or equal to this threshold, and prialarmStartupAlarm was equal to risingAlarm and risingOrFallingAlarm, the alarm was generated.

Procedure

  • This alarm is triggered only when the upper alarm monitoring threshold configured using the rmon prialarm command is reached. It is a user-configured monitoring alarm and does not affect services. Therefore, no action is required.

Related Information

None.

RMON_1.3.6.1.4.1.2011.1.3.4.0.2 prifallingAlarm

Description

RMON/3/FALLING:OID [oid] Private alarm table [alram-line-index] monitors [description] with the sample type being [sample-type], and the sampled alarm value [alarm-value] is less than or equal to [alarm-upper-limit].

The value of the alarm entity was lower than prialarmFallingThreshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.1.3.4.0.2 Minor communicationsAlarm(2)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

alram-line-index

Indicates the index of the alarm entry.

description

Indicates the description of the alarm entry.

sample-type

Indicates the type of the sampled alarm.

alarm-value

Indicates the alarm value.

alarm-upper-limit

Indicates the lower threshold of the alarm.

Impact on the System

System will not be affected.

Possible Causes

Cause 1:

If the current sampled value was less than or equal to this threshold, and the last sampled value was greater than this threshold, the alarm was generated.

Cause 2:

After this alarm entry became valid, when the first sampled value was less than or equal to this threshold, and the values of fallingAlarm, risingAlarm, and risingOrFallingAlarm were equal, the alarm was generated.

Procedure

  • This alarm is triggered only when the lower alarm monitoring threshold configured using the rmon prialarm command is reached. It is a user-configured monitoring alarm and does not affect services. Therefore, no action is required.