Alarm Handling

S9300, S9300E, and S9300X V200R013C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ASMNG

ASMNG

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.1 hwAsFaultNotify

Description

ASMNG/3/ASFAULT: OID [oid] The AS fails. (AS Index=[INTEGER], AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE], AS Fault Times=[INTEGER])

The AS went offline.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.1 Minor communicationsAlarm(2)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.
AS Fault Times Indicates the number of times the AS goes offline.

Impact on the System

Services are interrupted after the AS goes offline.

Possible Causes

Cause 1: The AS was powered off.

Cause 2: The link between the AS and parent failed.

Cause 3: Heartbeat packets between the AS and parent were lost.

Cause 4: The AS restarted.

Procedure

  1. Run the display as { all | name as-name | mac-address mac-address | vpn-instance information } command to check whether the AS is online.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  2. Check whether the AS is manually forced offline.

    • If so, the alarm handling ends.
    • If not, go to step 3.

  3. Check whether the AS is powered off or restarted.

    • If so, find out the cause.
      • Check whether the AS voltage is unstable. If so, add voltage regulators or adjust power supply.
      • If the AS connects to the parent across a network, the AS may restart because of attacks. To check whether attacks occur, log in to the AS and run the display as access configuration command. If the Current connected access controller field displays a different IP address than the currently used parent IP address, an attack from third-party devices occurs. To defend this attack, configure the DHCP snooping function on the intermediate device.
    • If not, go to step 4.

  4. Check whether the link between the AS and parent fails, for example, check whether the link is Down. If the link between the AS and parent is normal while the trap still exists.

    • If so, collect alarm information and configuration information, and then contact technical support personnel.

    • If not, the alarm handling ends.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.2 hwAsNormalNotify

Description

ASMNG/4/ASNORMAL: OID [oid] The AS recovers from a communication failure. (AS Index=[INTEGER], AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE])

The offline AS went online.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.2 Warning communicationsAlarm(2)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.

Impact on the System

Services are restored.

Possible Causes

The faulty link between the AS and parent recovered.

Procedure

  1. No action is required.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.3 hwAsAddOffLineNotify

Description

ASMNG/4/ASADDOFFLINE: OID [oid] The AS is added offline. (AS Index=[INTEGER], AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE])

An AS is added offline.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.3 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.

Impact on the System

None.

Possible Causes

An AS is added to the system.

Procedure

  1. No action is required.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.4 hwAsDelOffLineNotify

Description

ASMNG/4/ASDELOFFLINE: OID [oid] The AS is deleted offline. (AS Index=[INTEGER], AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE])

The AS was deleted offline.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.4 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.

Impact on the System

None.

Possible Causes

The AS was manually deleted offline.

Procedure

  1. No action is required.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.5 hwAsPortStateChangeToDownNotify

Description

ASMNG/4/ASPORTSTATEDOWN: OID [oid] AS interface turned into DOWN state. (AS Index=[INTEGER], AS IfIndex=[INTEGER], AS Name=[STRING], Slot Model=[STRING], AS MAC=[OPAQUE], Interface=[STRING], ifAdminStatus=[INTEGER], ifOperStatus=[INTEGER])

An AS port went Down.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.5 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS IfIndex Indicates the index of the port.
AS Name Indicates the AS name.
Slot Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.
Interface Indicates the port name.
ifAdminStatus Indicates the administrative status of the port.
ifOperStatus Indicates the operating status of the port.

Impact on the System

Services on the port are interrupted.

Possible Causes

Cause 1: A link failure occurred on the port.

Cause 2: The port was shut down manually.

Procedure

  1. Check whether the AS port was shut down manually, for example, whether the shutdown command was executed on this port or its cable was removed.

    • If so, the alarm handling ends.

    • If not, go to step 2.

  2. Replace the cable and optical module of this port to determine whether the existing cable or optical module is faulty.

    • If so, replace the existing cable or optical module.

    • If not, collect alarm information and configuration information, and then contact technical support personnel.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.6 hwAsPortStateChangeToUpNotify

Description

ASMNG/4/ASPORTSTATEUP: OID [oid] AS interface turned into UP state. (AS Index=[INTEGER], AS IfIndex=[INTEGER], AS Name=[STRING], Slot Model=[STRING], AS MAC=[OPAQUE], Interface=[STRING], ifAdminStatus=[INTEGER], ifOperStatus=[INTEGER])

An AS port went Up.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.6 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS IfIndex Indicates the index of the port.
AS Name Indicates the AS name.
Slot Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.
Interface Indicates the port name.
ifAdminStatus Indicates the administrative status of the port.
ifOperStatus Indicates the operating status of the port.

Impact on the System

None.

Possible Causes

The faulty link of the port recovered or the port was enabled manually.

Procedure

  1. No action is required.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.7 hwAsModelNotMatchNotify

Description

ASMNG/3/ASMODELNOTMATCH: OID [oid] The actual AS model of AS does not match the configured model. (AS Index=[INTEGER], AS Name=[STRING], AS MAC=[OPAQUE], AS Configured Model=[STRING], AS Actual Model=[STRING])

The actual AS model differed from the configured model.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.7 Minor processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
AS MAC Indicates the MAC address of the AS.
AS Configured Model Indicates the configured AS model.
AS Actual Model Indicates the actual AS model.

Impact on the System

The AS cannot go online or be registered.

Possible Causes

The actual AS model differed from the configured model.

Procedure

  1. Run the undo as name as-name command to delete the AS.
  2. Run the display as access configuration command to check Access management MAC.
  3. Run the as name as-name model as-model mac-address mac-address command to reconfigure the AS model. mac-address must be the same as Access management MAC displayed in the previous step.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.8 hwAsVersionNotMatchNotify

Description

ASMNG/2/ASVERSIONNOTMATCH: OID [oid] The software version of AS does not match the software version of Parent. (AS Index=[INTEGER], AS Name=[STRING], AS Software Version=[STRING], Parent Software Version=[STRING])

The software versions of the AS and parent are different.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.8 Major processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
AS Software Version Indicates the software version of the AS.
Parent Software Version Indicates the software version of the parent.

Impact on the System

If the software version of the AS differs from that of the parent, services cannot be deployed on the AS.

Possible Causes

The software versions of the AS and parent are different.

Procedure

  1. Check the software versions of the AS and parent.

    1. Run the display as { name as-name | mac-address mac-address } run-info command. The Software version field displays the AS software version.
    2. Run the display version command to check the parent software version.
    3. If the two software versions, go to step 2.

  2. Upgrade the AS software version online. For details, see Upgrading an AS in the S9300, S9300E, and S9300X V200R013C00 Configuration Guide - Device Management - SVF Configuration.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.9 hwAsNameConflictNotify

Description

ASMNG/3/ASNAMECONFLICT: OID [oid] The added AS name conflicts with the existed AS name. (conflicts AS Index=[INTEGER], conflicts AS Name=[STRING], conflicts AS MAC=[OPAQUE], Added AS MAC=[OPAQUE])

The name of the newly added AS conflicted with the name of an existing AS.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.9 Minor processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
conflicts AS Index Indicates the index of the existing AS.
conflicts AS Name Indicates the name of the existing AS.
conflicts AS MAC Indicates the MAC address of the existing AS.
Added AS MAC Indicates the MAC address of the newly added AS.

Impact on the System

The newly added AS cannot go online or be registered.

Possible Causes

The name of the newly added AS conflicted with the name of an existing AS.

Procedure

  • Run the as name as-name model as-model mac-address mac-address command to change the name of the newly added AS. By default, an AS uses the system default name-device MAC address as its name after it is connected to an SVF system.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.10 hwAsSlotModelNotMatchNotify

Description

ASMNG/3/ASSLOTMODELNOTMATCH: OID [oid] The actual slot model of AS does not match the configured model. (AS Index=[INTEGER], AS Name=[STRING], Slot configured Model=[STRING], Slot actual ID=[INTEGER], Slot actual Model=[STRING])

The actual device model of the AS is different from the configured one on the parent.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.10 Minor processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
Slot configured Model Indicates the configured device model.
Slot actual ID Indicates the actual slot ID.
Added Slot Model Indicates the actual device model.

Impact on the System

The AS cannot go online.

Possible Causes

The actual device model of the AS is different from the configured one on the parent.

Procedure

  • Replace this AS or run the slot slot-id1 replace-model model-name command to change the AS device model configured on the parent so that the configured and actual AS device models are the same.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.11 hwAsFullNotify

Description

ASMNG/4/ASFULL: OID [oid] The AS capacity on the Parent is full. (AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE], Maximum AS Number=[INTEGER])

The number of ASs in the system reached the maximum value.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.11 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.
Maximum AS Number Indicates the maximum number of ASs.

Impact on the System

New ASs cannot connect to the system.

Possible Causes

The number of ASs in the system reached the maximum value.

Procedure

  1. Run the display as all command to check current online ASs.
  2. Delete unnecessary ASs.

    1. Run the display uni-mng as name as-name interface brief command to check the fabric port for the specified ASs to be deleted.
    2. Run the display interface eth-trunk eth-trunk-id command to check member interfaces of the Eth-Trunk to which the fabric port is bound.
    3. Run the interface interface-type interface-number command to enter the member interface view.
    4. Run the shutdown command to shut down the member interface.
    5. Log in to the AS to be deleted and run the undo uni-mng enable command in the user view to restore the AS to the standalone mode. After this command is executed, the AS restarts.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.12 hwUnimngModeNotMatchNotify

Description

ASMNG/3/ASUNIMNGMODENOTMATCH: OID [oid] The unified management modes of AS and Parent are different. (AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE], AS State=[INTEGER], Parent State=[INTEGER])

The SVF enabling status of the AS and parent is different.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.12 Minor processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.
AS State Indicates the AS status.
Parent State Indicates the parent status.

Impact on the System

The AS cannot go online or be registered.

Possible Causes

The SVF enabling status of the AS and parent is different.

Procedure

  1. Check whether the SVF function has been enabled on the parent based on alarm parameters.

    • If so, go to step 2.
    • If not, go to step 3.

  2. If the SVF function has been enabled on the parent, the AS must be unconfigured and have the SVF function enabled through auto-negotiation.
  3. If the SVF function is not enabled on the parent, run the uni-mng command on the parent to enable the SVF function.
  4. Run the display_as_access_configuration command on the AS. If the AS mode field displays centralized or independent, the SVF function has been enabled on the AS.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.13 hwAsBoardAddNotify

Description

ASMNG/4/ASBOARDADD: OID [oid] A board is added into AS slot. (AS Index=[INTEGER], AS Name=[STRING], Added Slot Model=[STRING], Added SlotID=[INTEGER])

An AS slot ID was manually added on the parent.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.13 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
Added Slot Model Indicates the added AS model.
Added Slot ID Indicates the added slot ID.

Impact on the System

None.

Possible Causes

An AS slot ID was manually added on the parent.

Procedure

  1. No action is required.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.14 hwAsBoardDeleteNotify

Description

ASMNG/4/ASBOARDDELETE: OID [oid] A board is deleted from AS slot. (AS Index=[INTEGER], AS Name=[STRING], Delete dSlot Model=[STRING], Deleted Slot ID=[INTEGER])

An AS slot ID was manually deleted on the parent.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.14 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
Deleted Slot Model Indicates the deleted AS model.
Deleted Slot ID Indicates the deleted slot ID.

Impact on the System

None.

Possible Causes

An AS slot ID was manually deleted on the parent.

Procedure

  1. No action is required.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.15 hwAsBoardPlugInNotify

Description

ASMNG/4/ASBOARDPLUGIN: OID [oid] A board is installed into AS slot. (AS Index=[INTEGER], AS Name=[STRING], Plugged in Slot Model=[STRING], Plugged in Slot ID=[INTEGER])

A new member device joined the AS stack system.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.15 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
Plugged in Slot Model Indicates the AS model of the new member device.
Plugged in Slot ID Indicates the stack ID of the new member device.

Impact on the System

None.

Possible Causes

A new member device joined the AS stack system.

Procedure

  1. No action is required.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.16 hwAsBoardPlugOutNotify

Description

ASMNG/4/ASBOARDPLUGOUT: OID [oid] A board is removed from AS slot. (AS Index=[INTEGER], AS Name=[STRING], Pulled Out Slot Model=[STRING], Pulled Out Slot ID=[INTEGER])

A member device was removed from the AS stack system.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.16 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
Pulled Out Slot Model Indicates the model of the removed device.
Pulled Out Slot ID Indicates the stack ID of the removed device.

Impact on the System

None.

Possible Causes

A member device was removed from the AS stack system.

Procedure

  1. Check whether it is a normal situation that this AS was removed from the stack.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  2. Check whether stack ports are Up.

    • If so, collect alarm information and configuration information, and then contact technical support personnel.
    • If not, determine why stack ports cannot go Up and ensure that these ports are Up. Possible causes include: The shutdown command was executed on these ports; their cables were loose or faulty; their optical modules are faulty.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.17 hwAsInBlacklistNotify

Description

ASMNG/3/ASINBLACKLIST: OID [oid] The AS is not allowed to go online because it is in the blacklist. (AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE])

The MAC address of the AS was in the blacklist and the AS could not go online.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.17 Minor processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.

Impact on the System

Unauthorized ASs cannot go online or be registered.

Possible Causes

The MAC address of the AS was in the blacklist.

Procedure

  • Check whether the AS is authorized. If so, delete its MAC address from the blacklist. Run the undo blacklist mac-address command in the AS authentication view to delete the MAC address of this AS from the blacklist.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.18 hwAsUnconfirmedNotify

Description

ASMNG/3/ASUNCONFIRMED: OID [oid] The AS is not allowed to go online because it is not in the blacklist or whitelist. (AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE])

The AS was not in the blacklist or whitelist and did not pass the authentication.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.18 Minor processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.

Impact on the System

ASs with uncertain validity cannot go online or be registered.

Possible Causes

The AS was not in the blacklist or whitelist.

Procedure

  • Check whether the AS is authorized.

    • If not, the alarm handling ends.
    • If so, run the confirm { all | mac-address mac-address } command to confirm that unauthenticated AS pass the authentication.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.19 hwAsComboPortTypeChangeNotify

Description

ASMNG/4/ASCOMBOPORTTYPECHG: OID [oid] The type of AS interface changed. (AS Index=[INTEGER], AS IfIndex=[INTEGER], AS Name=[STRING], Interface=[STRING], ifType=[INTEGER])

The combo port type of the AS changed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.19 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS IfIndex Indicates the port index.
AS Name Indicates the AS name.
Interface Indicates the port name.
ifType Indicates the port type.

Impact on the System

None.

Possible Causes

The combo port type of the AS changed.

Procedure

  1. No action is required.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.20 hwAsOnlineFailNotify

Description

ASMNG/2/ASONLINEFAIL: OID [oid] AS fails to go online. (AS Name=[STRING], AS Model=[STRING], AS MAC=[OPAQUE], Reason ID=[INTEGER], Description=[STRING])

The AS fails to go online.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.20 Major processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Name Indicates the AS name.
AS Model Indicates the AS model.
AS MAC Indicates the MAC address of the AS.
Reason ID Indicates the reason ID.
Description Indicates the description.

Impact on the System

The AS cannot go online or be registered.

Possible Causes

  • No license was available on the parent or the license expired.
  • The models of member devices in the AS stack system were different.
  • The port connecting the parent to the AS was not bound to the corresponding indirectly-connected fabric port.
  • Ports of the AS were configured as member ports of an uplink fabric port.
  • An AS with the same ESN has gone online.

Procedure

  • No license was available on the parent or the license expired.

    Load a new license.

  • The models of member devices in the AS stack system were different.

    Use devices with the same model, port type, and port quantity to establish a stack system.

  • The port connecting the parent to the AS was not bound to the corresponding indirectly-connected fabric port.

    Bind the port connecting the parent to the AS to the corresponding indirectly-connected fabric port.

  • ASMNG/2/ASACCESSPORTINVALID: OID [oid] AS fails to go online.

    1. Check whether the configuration on the AS interface is necessary. If the configuration is necessary, go to step 2. If not, follow these instructions to delete the configuration:
      • If the interface has been added to an AS port group in the port group view, run the undo as name as-name interface interface-type interface-number in the port group view to remove the interface from the AS port group. Then, you must run the commit as name as-name command to commit the configuration in the uni-mng view, so that the service template configuration will be deleted from the interface.
      • If directly issued service configuration of the interface is found in the uni-mng view, run the undo direct-command view interface-type interface-number command command-text command in the uni-mng view to delete the configuration.
    2. If configuration on the interface is necessary, use another interface as the member port of the uplink fabric port.

  • An AS with the same ESN has gone online.

    Replace the AS with a new one.

Related Information

None

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.21 hwAsSlotIdInvalidNotify

Description

ASMNG/3/ASSLOTIDINVALID: OID [oid] The new member of the AS has an invalid slot ID. (AS Index=[INTEGER], AS Name=[STRING], Slot Model=[STRING], Slot ID=[INTEGER])

The stack ID of the new member device in the AS stack system was larger than 4.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.21 Minor processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Indicates the AS index.
AS Name Indicates the AS name.
Slot Model Indicates the AS model.
Slot ID Indicates the stack ID.

Impact on the System

The new member device restarts repeatedly.

Possible Causes

The stack ID of the new member device in the AS stack system was larger than 4.

Procedure

  1. Run the shutdown command on the interface connected to the new member device to shut down this interface or remove the cable of this interface.
  2. After the new member device starts, run the stack slot renumber command to change the slot ID of the new member device to less than or equal to 4.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.22 hwAsSysmacSwitchCfgErrNotify

Description

ASMNG/4/ASSYSMACSWITCHCFGERR: OID [oid] An error occurs in the configuration of AS system MAC switching delay. (AS Name=[STRING])

The MAC address switching mode of the AS stack system was not set to non-switching.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.22 Warning processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Name Indicates the AS name.

Impact on the System

After an active/standby switchover is performed, users connecting to the original active AS go offline.

Possible Causes

The MAC address switching mode of the AS stack system was not set to non-switching. If the MAC address switching delay was set to 0, MAC address switching would not be performed.

Procedure

  1. Check whether MAC address switching is required when an active/standby switchover is performed in the AS stack system.

    • If so, the alarm handling ends.
    • If not, go to step 2.

  2. Run the stack timer mac-address switch-delay 0 command in the system view to set the value of the MAC address switching timer to 0.

Related Information

None.

ASMNG_1.3.6.1.4.1.2011.5.25.327.31.2.2.23 hwAsSlotOnlineFailNotify

Description

ASMNG/2/ASSLOTONLINEFAIL: OID [oid] AS board fails to go online. (AS Index=[INTEGER], AS Name=[STRING], Slot Model=[STRING], Slot ID=[INTEGER], Reason ID=[INTEGER], Description=[STRING])

When an AS is a stack, some member switches in the stack failed to go online.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.327.31.2.2.23 Major processingErrorAlarm(4)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
AS Index Index of the AS.
AS Name Name of the AS.
Slot Model Device model of the AS.
Slot ID Device ID of the switch that failed to go online.
Reason ID ID of the online failure reason.
Description Online failure reason: The downstream port is configged to stack port.

Impact on the System

Some member switches in the stack cannot go online and restart repeatedly.

Possible Causes

When a stack functioned as an AS, the new member switch used downlink ports as stack member ports.

Procedure

  1. If the new member switch in the stack cannot go online, disconnect it from the stack and then run the display stack port command to check whether the configured stack member ports are downlink ports. If so, go to step 2.
  2. Change stack member ports from downlink ports to uplink ports.

    1. Run the shutdown interface { interface-type interface-number1 [ to interface-type interface-number2 ] } &<1-10> command in the logical stack port view to disable stack member ports.
    2. Run the undo port interface { interface-type interface-number1 [ to interface-type interface-number2 ] } &<1-10> enable command in the logical stack port view to remove stack member ports from the logical stack port.
    3. Run the port interface { interface-type interface-number3 [ to interface-type interface-number4 ] } &<1-10> enable command in the logical stack port view to add uplink ports to the logical stack port.

Translation