Alarm Handling

S9300, S9300E, and S9300X V200R013C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SYSMIB

SYSMIB

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.1 hwSysClockChangedNotification

Description

SYSMIB/4/CLOCK_CHANGE:OID [oid] System clock changed.

Indicates that the system clock is adjusted.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.1 Warning equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

Services will not be affected.

Possible Causes

This trap is used to record the adjustment of the system clock.

Procedure

  1. This alarm message is informational only, and no action is required.

Related Information

None

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.2 hwSysReloadNotification

Description

SYSMIB/4/RELOAD_END:[OID] Reload operation completed

Indicates that system has restarted completely.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.2 Warning equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

Services will not be affected.

Possible Causes

The device was restarted successfully by the NMS.

Procedure

  1. This alarm message is informational only, and no action is required.

Related Information

None

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.5.1 hwPatchErrorTrap

Description

SYSMIB/4/PAT_FAIL:OID [oid] Patch operation failed. (ErrorIndex=[GAUGE], ErrorSlot=[GAUGE], PatchIndex=[GAUGE], ErrorCode=[INTEGER], PatchFileName=[OCTET])

The patch operation failed due to the error in the patch file.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.5.1 Warning processingErrorAlarm(4)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

ErrorIndex

Indicates the error index.

ErrorSlot

Indicates the slot ID.

PatchFileName

Indicates the name of a patch file.

PatchIndex

Indicates the index of a patch file.

ErrorCode

Indicates an error code.

Impact on the System

The loaded patch is not validated.

Possible Causes

Cause 1:

The patch operation failed due to the error in the patch file.

Cause 2:

The patch operation is repeated.

Cause 3:

The running status of the patch is not Running.

Procedure

  1. Collect alarm information and configuration information, and then contact technical support personnel.

Related Information

None

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.5.2 hwPatchActiveOverTimeTrap

Description

SYSMIB/4/PAT_OVERTIME:OID [oid] The patch is active for 24 hours.

Indicates that the patch was activated for 24 hours by running the patch active command. The patch, however, was not in the running state by running the patch run command.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.5.2 Warning equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

The newly-loaded patches, after the restart of the system, cannot be validated after the next restart.

Possible Causes

Cause 1:

The patch was activated for 24 hours, but not set into the running state.

Cause 2:

The RPC was busy in communication or memory was insufficient.

Procedure

  1. Run the display patch-information command to check the patch status.
  2. Check whether the patch is in the running state.

    • If so, go to Step 6.

    • If not, go to Step 3.

  3. To determine whether to set the patch to the running state, check whether the patch needs to be validated in next restart.

    • If so, go to Step 4.

    • If not, go to Step 6.

  4. Check whether the patch status goes into the running state after running the patch run command.

    • If so, go to Step 6.

    • If not, go to Step 5.

  5. Collect alarm information and configuration information, and then contact technical support personnel.
  6. End.

Related Information

None

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.5.3 hwPatchMalfunctionComebackTrap

Description

SYSMIB/1/PAT_RECOVER:OID [oid] The patch fault is removed.

Indicates that a patch operation fails for the first time, and then succeeds in the next time. The patch operations include:
  1. Load the patch by running the patch load command.

  2. Activate the patch by running the patch active all command.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.5.3 Critical equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

Services will not be affected.

Possible Causes

A patch operation fails for the first time, and then succeeds in the next time.

Procedure

  1. This alarm message is informational only, and no action is required.

Related Information

None

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.8 hwSysSlaveSwitchSuccessNotification

Description

SYSMIB/3/SWITCH_SUCCESS:OID [oid] Slave switchover success.

Succeeded in performing the master-slave switchover.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.8 Minor equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

System will not be affected.

Possible Causes

The master-slave switchover is performed manually.

Procedure

  1. This alarm message is informational only, and no action is required.

Related Information

None.

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.9 hwSysSlaveSwitchFailNotification

Description

SYSMIB/3/SWITCH_FAIL:OID [oid] Slave switchover fail.

Failed to perform the master-slave switchover.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.9 Minor equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

System will not be affected.

Possible Causes

  • The master-slave switchover function is not enabled on the device.

  • The slave main control board is unavailable.

  • An error causes the master-slave switchover to be failed.

Procedure

  1. Run the display current-configuration command to check whether the master-slave switchover function is enabled on the device.

    • If so, go to Step 4.

    • If not, go to Step 2.

  2. Run the display device command to check whether the slave main control board on the device is unavailable.

    • If so, go to Step 4.

    • If not, go to Step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.

Related Information

None.

SYSMIB_1.3.6.1.4.1.2011.5.25.19.2.10 hwSysIssuNotification

Description

SYSMIB/4/ISSUCONDITION:OID [OID] ISSU upgrade complete. (issuState=[integer], issuConditionCheck=[integer])

ISSU upgrade was complete.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.19.2.10 Warning equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

issuState

Indicates the ISSU upgrade state.

The value can only be 1, indicating that the device is not in the ISSU upgrade state.

issuConditionCheck

Indicates the ISSU check status.
  • The value 1 indicates that no error is detected in the ISSU check.
  • The value 2 indicates that the standby main control board is not in the real-time backup state.
  • The value 3 indicates that some LPU does not work properly.
  • The value 5 indicates other errors.

Impact on the System

Services will not be affected.

Possible Causes

ISSU upgrade was complete.

Procedure

  1. This alarm is informational only, and no action is required.

Related Information

None.