Alarm Handling

S9300, S9300E, and S9300X V200R013C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FM

FM

FM_1.3.6.1.4.1.2011.5.25.180.2.1 hwAlarmTargetHostDel

Description

FM/4/TARGETHOST_DEL:OID [oid] Target host [octet] was deleted.

The target host was deleted.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.180.2.1 Warning environmentalAlarm(6)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

[octet]

Indicates the IP address of a target host.

Impact on the System

The system will not be affected.

Possible Causes

The target host was deleted.

Procedure

  1. This alarm information is informational only, and no action is required.

Related Information

None.

FM_1.3.6.1.4.1.2011.5.25.180.2.2 hwAlarmStorm

Description

FM/4/ALARM_STORM:OID [oid] There are excessive traps, which form a trap storm.

Excessive traps were generated, which caused a trap storm.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.180.2.2 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

If a trap storm is caused, traps will accumulate and the trap queue will reach full. If such a situation lasts for a long time, the last traps in the queue may fail to be sent.

Possible Causes

The number of traps received by the system at one time reached the upper limit, which caused a trap storm.

Procedure

  1. Run the display alarm active command to query current alarms.
  2. Record the information about the traps that are reported frequently.
  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.