Alarm Handling

S9300, S9300E, and S9300X V200R013C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LINE

LINE

LINE_1.3.6.1.4.1.2011.5.25.207.2.1 hwVtyNumExceed

Description

LINE/4/VTYUSERREACHMAX:OID [oid] The number of login users reaches the maximum limit. (MaxUserNum=[INTEGER])

The number of login users through Telnet reaches the maximum limit.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.207.2.1 Warning equipmentAlarm(5)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

MaxUserNum

Indicates the maximum number of users who can log in.

Impact on the System

More users cannot log in to the device through Telnet.

Possible Causes

The number of Telnet connections reaches the maximum limit set by the user.

Procedure

  1. Run the display user-interface maximum-vty command to view the maximum number of VTY users. This number can be configured using the user-interface maximum-vty command.
  2. Run the display users command to check whether the number of login Telnet users exceeds the upper threshold.

    • If the number of login Telnet users exceeds the upper threshold, go to Step 2.
    • If the number of login Telnet users does not exceed the upper threshold, go to Step 3.

  3. Reduce the number of login users through Telnet.
  4. End.

Related Information

None

LINE_1.3.6.1.4.1.2011.5.25.207.2.2 hwUserLogin

Description

LINE/5/VTYUSERLOGIN:OID [oid] A user login. (UserIndex=[INTEGER], UserName=[STRING], UserIP=[STRING], UserChannel=[STRING])

This object indicates notification information about user login.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.207.2.2 Indeterminate equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

UserIndex

Indicates the user index.

UserName

Indicates the user name.

When the device fails to obtain the user name, for example, in a password-based user authentication scenario, asterisks (**) are used to indicate the user name.

UserIP

Indicates the IP address of a user.

When the device fails to obtain the user IP address, for example, in a scenario where the user logs in using a Console interface or AUX interface, asterisks (**) are used to indicate the IP address.

UserChannel

Indicates the channel used by the user.

Impact on the System

This alarm message is informational only, and no action is required.

Possible Causes

When a user logs in to the device through Telnet, a notification is reported.

Procedure

  1. This alarm message is informational only, and no action is required.

Related Information

None

LINE_1.3.6.1.4.1.2011.5.25.207.2.3 hwUserLoginFail

Description

LINE/5/VTYUSERLOGINFAIL:OID [oid] A user login fail. (UserIndex=[INTEGER], UserName=[STRING], UserIP=[STRING], UserChannel=[STRING])

A user failed to log in to the server.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.207.2.3 Indeterminate equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

UserIndex

Index of a user

UserName

Name of a user

When the device fails to obtain the user name, for example, in a password-based user authentication scenario, asterisks (**) are used to indicate the user name.

UserIP

IP address of a user

When the device fails to obtain the user IP address, for example, in a scenario where the user logs in using a Console interface or AUX interface, asterisks (**) are used to indicate the IP address.

UserChannel

Channel for login

Impact on the System

The system will not be affected.

Possible Causes

A user incorrectly enters the user name or password for three consecutive times during Telnet login, causing a login failure and triggering the alarm.

Procedure

  1. Enter the user name and password.

Related Information

None.

LINE_1.3.6.1.4.1.2011.5.25.207.2.4 hwUserLogout

Description

LINE/5/VTYUSERLOGOUT:OID [oid] A user logout. (UserIndex=[INTEGER], UserName=[STRING], UserIP=[STRING], UserChannel=[STRING])

The user logged out of the device.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.207.2.4 Indeterminate equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

UserIndex

Indicates the user index.

UserName

Indicates the user name.

When the device fails to obtain the user name, for example, in a password-based user authentication scenario, asterisks (**) are used to indicate the user name.

UserIP

Indicates the IP address of a user.

When the device fails to obtain the user IP address, for example, in a scenario where the user logs in using a Console interface or AUX interface, asterisks (**) are used to indicate the IP address.

UserChannel

Indicates the channel used by the user.

Impact on the System

This log message indicates a normal situation, and no action is required.

Possible Causes

When a user logs out of the device, a notification is reported.

Procedure

  1. This alarm message is informational only, and no action is required.