Alarm Handling

S9300, S9300E, and S9300X V200R013C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
INFO

INFO

INFO_1.3.6.1.4.1.2011.5.25.212.2.2 hwICLogFileAging

Description

INFO/4/IC_LOGFILE_AGING: OID [OID] One log file is deleted due to aging. (LogFileName=[octet])

A log file aged and then was deleted.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.212.2.2 Warning

other(1)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

LogFileName

Indicates the name and path of a log file.

Impact on the System

System performance will not be affected.

Possible Causes

  • Cause 1: The number of recorded compressed files exceeded the threshold.
  • Cause 2: The storage of log files was less than 30 MB.

Procedure

  • This trap message is informational only, and no action is required.

Related Information

None.

INFO_1.3.6.1.4.1.2011.5.25.212.2.4 hwICLogBufferLose

Description

INFO/2/ICLogBufferLose: OID [OID] Some logs in the buffer were lost due to storage space insufficiency.

Some logs in the log buffer were lost because of storage space insufficiency.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.212.2.4 Major

other(1)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

Impact on the System

The system will not be affected.

Possible Causes

The storage space was insufficient, but no log files were aged.

Procedure

  1. Delete unwanted files or enlarge the remaining disk space.

Related Information

None