Alarm Handling

S9300, S9300E, and S9300X V200R013C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SMLK

SMLK

SMLK_1.3.6.1.4.1.2011.5.25.42.5.2.1 hwSmartLinkLinkSwitch

Description

SMLK/4/SMLK_STATUS_TRAP:OID [oid] Smart link group [INTEGER] status turned to [STRING].

The Smart Link group status switches.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.42.5.2.1 Warning equipmentAlarm(5)

Parameters

Name Meaning
[oid] Indicates the MIB object ID of the alarm.
[INTEGER] Indicates the Smart Link group index.
[STRING] Indicates the interface role in a Smart Link group, which can be idle, master, or slave.

Impact on the System

The service traffic is switched to the active link.

Possible Causes

Cause 1:

Smart Link is enabled or disabled.

Cause 2:

The status of active and standby links changes.

Cause 3:

The interface status in the Smart Link group is switched manually.

Procedure

  1. Check whether the manual configuration results in the fault, such as Smart Link enabling, Smart Link disabling, or interface shutdown in the Smart Link group.

    • If yes, go to step 6.
    • If not, go to step 2.

  2. Check whether cables of active and standby links of the Smart Link group are disconnected.

    • If yes, go to step 3.
    • If not, go to step 4.

  3. Connect cables correctly. Then check whether the alarm is cleared.

    • If yes, go to step 6.
    • If not, go to step 4.

  4. Run the display smart-link group { all | group-id } command to check whether the interface in the Smart Link group is Down.

    • If the interface is Down, make the interface Up.
    • If not, go to step 5.

  5. Contact technical support personnel.
  6. End.

Related Information

None

SMLK_1.3.6.1.4.1.2011.5.25.42.5.2.2 hwSmartLinkInactiveLinkFail

Description

SMLK/4/SMLK_SLAVEPORT_TRAP:OID [OID] [STRING] link port [INTEGER1] of smart link group [INTEGER2] was abnormal, the port is [OCTET].

A fault occurs on the standby link of the Smart Link group.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.42.5.2.2 Warning equipmentAlarm(5)

Parameters

Name Meaning
OID Indicates the MIB object ID of the alarm.
STRING Indicates the status of the interface in the Smart Link group, which can be active or inactive.
INTEGER1 Indicates the index of the interface in the Smart Link group.
INTEGER2 Indicates the Smart Link group index.
OCTET Indicates the name of the interface in the Smart Link group.

Impact on the System

The service traffic is switched to the active link.

Possible Causes

Cause 1:

The link of the slave interface in the Smart Link group is faulty.

Cause 2:

The slave interface in the Smart Link group is changed to Down by using commands.

Procedure

  1. Check whether the shutdown (interface view) command is configured on the interface.

    • If so, go to step 5.
    • If not, go to step 2.

  2. Check whether cables of standby links of the Smart Link group are disconnected.

    • If yes, go to step 3.
    • If not, go to step 4.

  3. Connect cables correctly. Then check whether the alarm is cleared.

    • If yes, go to step 5.
    • If not, go to step 4.

  4. Collect alarm information and configuration information, and then contact technical support personnel.
  5. End.

SMLK_1.3.6.1.4.1.2011.5.25.42.5.2.3 hwSmartLinkInactiveLinkResume

Description

SMLK/4/SMLK_SLAVEPORT_TRAP:OID [OID] [STRING] link port [INTEGER1] of smart link group [INTEGER2] was normal, the port is [OCTET].

A fault on the standby link of the Smart Link group is rectified.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.42.5.2.3 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
[STRING] Indicates the status of the interface in the Smart Link group, which can be active or inactive.
[INTEGER1] Indicates the index of the interface in the Smart Link group.
[INTEGER2] Indicates the Smart Link group index.
[OCTET] Indicates the name of the interface in the Smart Link group.

Impact on the System

The service traffic is switched to the active link.

Possible Causes

The slave interface in the Smart Link group is Up.

Procedure

  1. This alarm is informational and no action is required.

SMLK_1.3.6.1.4.1.2011.5.25.42.5.2.4 hwSmartLinkGroupEnable

Description

SMLK/4/SMLK_GROUP_TRAP:OID [oid] Smart link group [INTEGER] was [STRING].

The Smart Link group is enabled.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.42.5.2.4 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
[INTEGER] Indicates the Smart Link group index.
[STRING] Indicates the Smart Link group status, which can be enable.

Impact on the System

The service traffic is switched to the active link.

Possible Causes

Smart Link is enabled.

Procedure

  • This alarm is informational and no action is required.

SMLK_1.3.6.1.4.1.2011.5.25.42.5.2.5 hwSmartLinkGroupDisable

Description

SMLK/4/SMLK_GROUP_TRAP:OID [OID] Smart link group [INTEGER] was [STRING].

The Smart Link group is disabled.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.42.5.2.5 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
[INTEGER] Indicates the Smart Link group index.
[STRING] Indicates the Smart Link group status, which can be disable.

Impact on the System

The service traffic is switched to the active link.

Possible Causes

Smart Link is disabled.

Procedure

  • This alarm is informational and no action is required.