Alarm Handling

S9300, S9300E, and S9300X V200R013C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SINDEX

SINDEX

SINDEX_1.3.6.1.4.1.2011.5.25.110.2.0.2 hwNetStreamIndexUsedUp

Description

SINDEX/3/IFINDEX: OID [oid] ShortIFIndex is used up.

When the total 65535 indexes were allocated but more indexes were needed for the creation of new interfaces, the trap was generated.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.110.2.0.2 Minor equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

When the Netstream module sends flow information to the NMS, the flow information contains the 16-bit index of an interface. Then, the NMS resolutes the interface name according to the index. In normal situations, a 16-bit index is allocated to each interface, and the total 65535 interfaces will obtain indexes. If the number of interfaces is more than 65535, the traffic statistics sent to the NMS cannot carry the 16-bit index. As a result, the NMS fails to resolute the interface name according to the index and therefore cannot charge and monitor the network normally.

Possible Causes

The interfaces were more than the interface index resources that could be allocated. The index resources were used up.

Procedure

  1. Run the display ip interface brief command to check the logical interface that is in the Down state. Run the undo interface command to delete the unwanted logical interface.
  2. Re-create an interface to be used, and check whether the trap is displayed.

    • If so, go to Step 3.
    • If not, go to Step 4.

  3. Collect alarm information and configuration information, and then contact technical support personnel.