No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

S9300, S9300E, and S9300X V200R013C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DLDP

DLDP

DLDP_1.3.6.1.4.1.2011.5.25.173.3.2 hwDldpLinkResume

Description

DLDP/4/DETECTUNIDIRECT(t): OID [oid] The port is detected in two way status. (IfIndex=[integer], IfName=[STRING])

A unidirectional link fault was removed, and two connected devices can send and receive packets correctly.

A bidirectional communication alarm is generated when the device that receives packets from the other device detects the bidirectional communication state.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.173.3.2 Warning equipmentAlarm(5)

Parameters

Name Meaning
[oid] Indicates the MIB object ID of the alarm.
IfIndex Indicates the interface index.
IfName Indicates the interface name.

Impact on the System

The interface sends and receives packets correctly.

Possible Causes

1. Optical fibers or twisted-pair cables were connected correctly.

2. The cable connection fault was rectified.

Procedure

  • This alarm message is informational only, and no action is required.

DLDP_1.3.6.1.4.1.2011.5.25.173.3.3 hwDldpLoopDetect

Description

DLDP/4/DETECTUNIDIRECT(t): OID [oid] The port is detected in Loop status. (IfIndex=[integer], IfName=[STRING])

A loop is detected on an interface due to incorrect fiber connection or a hub fault.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.173.3.3 Warning equipmentAlarm(5)

Parameters

Name Meaning
[oid] Indicates the MIB object ID of the alarm.
IfIndex Indicates the index of the interface where the loop alarm is generated.
IfName Indicates the name of the interface where the loop alarm is generated.

Impact on the System

Packet forwarding on the interface is affected.

Possible Causes

The signals transmitted from the Tx end of an optical interface are received by the Rx end of the interface due the either of the following reasons:

  • The Tx end and Rx end of the interface is connected on a fiber.
  • A fault occurs on the hub connected to the interface.

Procedure

  1. Run the display dldp command to check the DLDP status on the interface.

    • If the DLDP port state field displays advertisement, the loop has been removed. Go to 4.

    • If the DLDP port state field displays loop, a loop link exists. Go to 2.

  2. Check whether the fibers on the interface are connected correctly or whether the hub connected to the interface is working properly.

    (1) If the fibers are corrected incorrectly or the hub fails, connect the fibers correctly or fix the hub fault, and go to 1.

    (2) If the fibers are connected correctly and the hub connected to the interface is working properly, go to 3.

  3. Contact technical support personnel.
  4. End.

DLDP_1.3.6.1.4.1.2011.5.25.173.3.4 hwDldpLoopResume

Description

DLDP/4/DETECTUNIDIRECT(t): OID [oid] The port is detected exit Loop status. (IfIndex=[integer], IfName=[STRING])

The loop on an interface has been removed or the interface is shut down.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.173.3.4 Warning equipmentAlarm(5)

Parameters

Name Meaning
[oid] Indicates the MIB object ID of the alarm.
IfIndex Indicates the index of the interface where the alarm is generated.
IfName Indicates the name of the interface where the alarm is generated.

Impact on the System

The loop on the interface has been removed.

  • If the fibers on the interface are connected correctly and the loop is removed, services on the interface are resumed.
  • If the interface is shut down, the interface cannot work.

Possible Causes

1:

The fibers on the interface are connected correctly and the loop is removed.

2:

The interface is shut down.

Procedure

  1. Run the display dldp command to check the DLDP status on the interface.

    • If the DLDP port state field displays advertisement, the loop has been removed. Go to 4.

    • If the DLDP port state field displays inactive, go to 2.

  2. Check whether the interface is in Down state.

    (1) If so, connect the fibers correctly. When the interface goes Up, go to 1.

    (2) If not, go to 3.

  3. Contact technical support personnel.
  4. End.
Translation
Download
Updated: 2019-04-09

Document ID: EDOC1100065855

Views: 5093

Downloads: 6

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share