Alarm Handling

S9300, S9300E, and S9300X V200R013C00

This document provides the explanations, causes, and recommended actions of alarms on the product.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
PM

PM

PM_1.3.6.1.4.1.2011.5.25.190.1.9.1 hwPMStatisticsTaskThresholdTriggerAlarm

Description

PM/4/hwPMThresholdCross: OID [OID] The statistics value exceeded the threshold. (StatisticsTaskName=[OCTET], StatisticsTaskName=[OCTET], StatisticsObjectType=[GAUGE], StatisticsObjectName=[OCTET], StatisticsTaskName=[OCTET], StatisticsObjectType=[GA UGE], StatisticsIndicatorID=[GAUGE], StatisticsTaskName=[OCTET], StatisticsObjectType=[GAUGE], StatisticsIndicatorID=[GAUGE], TriggerType=[integer], StatisticsCycle=[integer], TriggerHighValue=[GAUGE], TriggerLowValue=[GAUGE], CurrentHighValue=[GAUGE], CurrentLowValue=[GAUGE])

Performance statistics exceeded the alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.190.1.9.1 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

StatisticsTaskName

Name of a performance statistics task

StatisticsObjectType

Type of a performance statistics object

StatisticsObjectName

Name of a performance statistics object

StatisticsIndicatorID

Indicator ID of a performance statistics task

TriggerType

Type of threshold rules for performance statistics tasks

StatisticsCycle

Interval for collecting performance statistics

TriggerHighValue

The leftmost 32 bits of the threshold when the alarm is triggered

TriggerLowValue

The rightmost 32 bits of the threshold when the alarm is triggered

CurrentHighValue

The leftmost 32 bits of the current performance statistics data

CurrentLowValue

The rightmost 32 bits of the current performance statistics data

Impact on the System

The threshold alarm indicates that the operating status of monitored objects may be abnormal.

Possible Causes

Statistics on performance indicators of monitored objects meet the rules for triggering the threshold alarm.

Procedure

  1. View the alarm information, analyze the operating status of corresponding alarm services, and restores monitored objects to the normal state.

Related Information

None

PM_1.3.6.1.4.1.2011.5.25.190.1.9.2 hwPMStatisticsTaskThresholdClearAlarm

Description

PM/4/hwPMThresholdClear: OID [OID] The threshold alarm is cleared. (StatisticsTaskName=[OCTET], StatisticsTaskName=[OCTET], StatisticsObjectType=[GAUGE], StatisticsObjectName=[OCTET], StatisticsTaskName=[OCTET], StatisticsObjectType=[GAUGE], StatisticsIndicatorID=[GAUGE], StatisticsTaskName=[OCTET], StatisticsObjectType=[GAUGE], StatisticsIndicatorID=[GAUGE], TriggerType=[intege r], StatisticsCycle=[integer], ResumeHighValue=[GAUGE], ResumeLowValue=[GAUGE], CurrentHighValue=[GAUGE], CurrentLowValue=[GAUGE])

The threshold alarm is cleared.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.190.1.9.2 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

StatisticsTaskName

Name of a performance statistics task

StatisticsObjectType

Type of a performance statistics object

StatisticsObjectName

Name of a performance statistics object

StatisticsIndicatorID

ID of a performance statistics task

TriggerType

Type of threshold rules for performance statistics tasks

StatisticsCycle

Interval for collecting performance statistics

ResumeHighValue

The leftmost 32 bits of the threshold when the alarm is cleared

ResumeLowValue

The rightmost 32 bits of the threshold when the alarm is cleared

CurrentHighValue

The leftmost 32 bits of the current performance statistics data

CurrentLowValue

The rightmost 32 bits of the current performance statistics data

Impact on the System

The alarm indicates that services are recovered.

Possible Causes

Indicators of the monitored objects are recovered.

Procedure

  1. This alarm message is informational only, and no action is required.

Related Information

None

PM_1.3.6.1.4.1.2011.5.25.190.1.13.1 hwPMMeasureExceed

Description

PM/3/hwPMMeasureExceed:OID [OID] The number of statistical indexes has reached the upper limit.

The number of indicators had reached the upper limit.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.190.1.13.1 Minor

qualityOfServiceAlarm

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

Impact on the System

The system will not be affected.

Possible Causes

The number of indicators had reached the upper limit.

Procedure

  1. Run the display this command in the PM view to check current statistical tasks and bound instances.
  2. Run one or more of the following commands to reduce performance statistics on the device:

    • Run the undo statistics-task task-name command to delete an unwanted statistical task.
    • Run the undo binding instance-type instance-type instance-type { all | instance { instance-name } & <1-5> } command to delete unwanted performance instances bound to a specified statistical task.
    • Run the measure disable [ measure-name ] command to disable unwanted measurement indicators in a statistical task.

Related Information

None

Translation
Download
Updated: 2019-04-09