Configuration Guide - Reliability

S9300, S9300E, and S9300X V200R013C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, NSR Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Licensing Requirements and Limitations for BFD

Licensing Requirements and Limitations for BFD

Involved Network Elements

Other network elements are required to support BFD functions.

Licensing Requirements

BFD is a basic feature of a switch and is not under license control.

Version Requirements

Table 2-6  Products and versions supporting BFD
Product Product Model Version

S9300

S9303, S9306, and S9312

V100R002, V100R003, V100R006(C00&C01), V200R001C00, V200R002C00, V200R003C00, V200R005C00SPC300, V200R006C00, V200R007C00, V200R008(C00&C10), V200R009C00, V200R010C00, V200R011C10, V200R012C00, V200R013C00

S9310

V200R010C00, V200R011C10, V200R012C00, V200R013C00

S9300E

S9303E, S9306E, and S9312E

V200R001C00, V200R002C00, V200R003C00, V200R005C00SPC300, V200R006C00, V200R007C00, V200R008(C00&C10), V200R009C00, V200R010C00, V200R011C10, V200R012C00, V200R013C00

S9300X

S9310X

V200R010C00, V200R011C10, V200R012C00, V200R013C00

NOTE:
For details about software mappings, visit Hardware Query Tool and search for the desired product model.

Feature Limitations

If a loop occurs on the path detected by BFD, the change of the network topology where the loop exists may cause the BFD session to flap at one time.

When BFD is bound to a sub-interface, only dot1q terminal sub-interface supports BFD function.

When the BFD session is bound to the Eth-Trunk and the detection time is less than 300 ms, you are not advised to add or delete Eth-Trunk member interfaces. Otherwise, the BFD session may flap.

To implement 50-ms switching, the device must support the 3.3-ms interval for sending and receiving BFD packets. The configuration is supported in the following situations:
  • The MPU is equipped with the LE0MFSUA subcard or the MPU is LH2D2SRUDC00 or LE2D2SRUDC01.
  • For the S9306 and S9312, you need to first run the assign system-resource-mode static command to configure the switch to statically allocate module resources.