Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Verifying the CFM Configuration

Verifying the CFM Configuration

Prerequisites

The configuration of basic Ethernet CFM functions is complete.

Procedure

  • Run the display cfm md [ md-name ] command to verify the MD configuration.
  • Run the display cfm ma [ md md-name [ ma ma-name ] ] command to verify detailed information about an MA.
  • Run the display cfm mep [ md md-name [ ma ma-name [ mep-id mep-id ] ] ] command to verify detailed information about a MEP.
  • Run the following commands to view detailed information about an RMEP.

    • display cfm remote-mep md md-name ma ma-name mep-id mep-id

    • display cfm remote-mep [ md md-name [ ma ma-name ] ] [ cfm-state { up | down | disable } ]

  • Run the display cfm mip [ interface interface-type interface-number | level level ] command to verify information about a MIP.
  • Run the display cfm default md command to verify the default MD configuration.
  • Run the display cfm error-info error-type unexpected-mep [ md md-name ma ma-name mep-id mep-id ] command to verify incorrect configurations of the specified error type.
  • Run the display cfm mp-info [ interface interface-type interface-number [ level md-level ] [ inward | outward ] [ vlan vlanid | no-associated-vlan ] ] command to verify information about CFM objects on the specified interface or VLAN.
  • Run the display oam global configuration command to verify the MP address model.