Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DLDP Cannot Discover a Directly Connected Neighbor

DLDP Cannot Discover a Directly Connected Neighbor

Common Cause

This fault is commonly caused by one of the following:

  • The link between the local device and directly connected neighbor failed.

  • DLDP is disabled on the remote device.

  • DLDP parameters on the local and the remote devices are different.

Procedure

  1. Run the display interface interface-type interface-number command to check the status of the interface that cannot discover the remote device.

    • If the interface status is Down, rectify the failure.

    • If the interface status is Up, go to step 2.

  2. Run the display dldp command to see whether DLDP is enabled globally, that is, run the display this command in the interface view to check whether the output information contains the dldp enable field. If so, DLDP has been enabled on the interface; if not, DLDP is disabled on the interface.

    • If DLDP is not enabled globally or on an interface, run the dldp enable command in the corresponding view to enable DLDP.

    • If DLDP is enabled, go to step 3.

  3. Run the display dldp command to check whether the DLDP parameters on the local and remote devices are the same.

    Field

    Method

    DLDP interval

    Check whether the intervals on both ends are the same. If the intervals for sending DLDPDUs on both ends are different, run the dldp interval interval command in the system view on both devices to set the same interval on both devices.

    DLDP authentication-mode

    Check whether authentication modes and passwords on both ends are the same. If the two devices use different authentication modes or passwords, run the dldp authentication-mode { md5 md5-password | sha sha-password | simple simple-password | none } command in the system view to set the same authentication mode and password on both devices.