Configuration Guide - Reliability

S9300, S9300E, and S9300X V200R013C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, NSR Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring NSR

Configuring NSR

Applicable Environment

When the control plane of the system becomes faulty, NSR can switch entries on the faulty control plane to the backup control plane, which is independent of neighbors and does not interrupt route processing.

The system-level NSR function is used in the following situations:

  • A system fault triggers the active/standby switchover of MPUs.

  • When upgrading the software or maintaining the system, the administrator manually triggers the active/standby switchover of MPUs.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run switchover mode nonstop-routing

    The HA working mode is set to NSR.

Verifying the Configuration

  • Run the display switchover mode command to verify the HA working mode of the system.

  • Run the display ip routing-table [ verbose ] command to verify routing information after the active/standby switchover of MPUs.

  • Run the display fib verbose command to verify forwarding information after the active/standby switchover of MPUs.