Configuration Guide - Reliability

S9300, S9300E, and S9300X V200R013C00

This document describes the configurations of Reliability, including BFD Configuration, VRRP Configuration, NSR Configuration, DLDP Configuration, Smart Link and Monitor Link Configuration, MAC Swap Loopback Configuration, EFM Configuration, CFM Configuration, Y.1731 Configuration.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring 802.1ag MAC Ping

Configuring 802.1ag MAC Ping

Context

Similar to IP ping, 802.1ag MAC ping monitors connectivity of a path between a MEP and an RMEP.

802.1ag MAC ping can be only implemented on the network where the MD, MA, and MEP are configured.

Procedure

  1. A device is usually configured with multiple MDs and MAs. To accurately detect connectivity of a link between two or more devices, perform either of the following operations.

    • MA view:

      1. Run system-view

        The system view is displayed.

      2. Run cfm md md-name

        The MD view is displayed.

      3. Run ma ma-name

        The MA view is displayed.

      4. Run ping mac-8021ag mep mep-id mep-id { md md-name ma ma-name { mac mac-address | remote-mep mep-id mep-id } | mac mac-address | remote-mep mep-id mep-id } [ -c count | interface interface-type interface-number | -s packetsize | -t timeout | -p priority-value ] *

        Connectivity between a MEP and an RMEP or a MIP is monitored.

      • The ping mac-8021ag command without md md-name and ma ma-name specified checks connectivity of links in a specified MA.

      • The ping mac-8021ag command with md md-name and ma ma-name specified checks connectivity of links based on the configured MA and MD.

    • All views except the MA view:

      Run ping mac-8021ag mep mep-id mep-id md md-name ma ma-name { mac mac-address | remote-mep mep-id mep-id } [ -c count | interface interface-type interface-number | -s packetsize | -t timeout | -p priority-value ] *

      Connectivity between a MEP and an RMEP or a MIP is monitored.

    When performing 802.1ag MAC ping, ensure that:

    • The MA has been associated with a VLAN.

    • The MEP has been configured in the MA.

    • The outbound interface (if specified) cannot be the interface on which an inward-facing MEP is configured. The interface must join the VLAN associated with the MA.

    • If the destination node is an RMEP, either mac mac-address or remote-mep mep-id mep-id can be specified. If remote-mep mep-id mep-id is specified, the RMEP must have been created using the remote-mep command and the bridge MAC address of the device on which the RMEP is located must be specified.

    • If the destination node is a MIP, specify mac mac-address.

    An intermediate device on a link is only used to forward LBMs and LBR messages; therefore, the intermediate device does not need to be configured with the MD, MA, or MEP.