This document describes the configurations of Device Management, including device status query, hardware management, Stack, SVF, cloud-based management, PoE, OPS, energy-saving management, information center, fault management, NTP.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Example for Configuring Fault Management

Example for Configuring Fault Management

Networking Requirements

As shown in Figure 10-1, the route between the device and the NMS is reachable. Users want to view alarms generated by the device on the NMS in real time. Users must monitor the LinkDown alarm to ensure the normal interconnection of the device.

Figure 10-1  Networking for configuring alarm management

Configuration Roadmap

The configuration roadmap is as follows:

Configure the alarm severity to critical, allowing users to monitor LinkDown alarms on the NMS in real time based on the alarm filtering rules.

Procedure

  1. Configure an SNMPv2 user and an NMS host.

    <HUAWEI> system-view
    [HUAWEI] sysname Switch
    [Switch] snmp-agent
    [Switch] snmp-agent sys-info version v2c
    [Switch] snmp-agent target-host trap address udp-domain 10.1.1.1 params securityname public
    [Switch] snmp-agent trap enable feature-name ifnet trap-name linkdown
    [Switch] snmp-agent trap enable feature-name ifnet trap-name linkup
    

  2. Set the severity for the linkDown alarm to critical.

    [Switch] alarm
    [Switch-alarm] alarm linkDown severity critical
    [Switch-alarm] return
    

  3. Verify the configuration.

    # Run the display alarm information [ name alarm-name ] command to view the alarm configuration.

    <Switch> display alarm information name linkdown
    **********************************                                                                                                  
      AlarmName: linkDown                                                                                                               
      AlarmType: Alarm                                                                                                                  
      AlarmLevel: Critical                                                                                                              
      Suppress Period: NA                                                                                                               
      CauseAlarmName: NA                                                                                                                
      Match VB Name: ifIndex                                                                                                            
    *********************************
    <Switch> display alarm information name linkup
    **********************************                                                                                                  
      AlarmName: linkUp                                                                                                                 
      AlarmType: Resume Alarm                                                                                                           
      AlarmLevel: Cleared                                                                                                               
      Suppress Period: NA                                                                                                               
      CauseAlarmName: linkDown                                                                                                          
      Match VB Name: ifIndex                                                                                                            
    ********************************** 

Configuration Files

Configuration file of the Switch

#                                                                                                                                   
sysname Switch                                                                                                                      
#
snmp-agent                                                                                                                          
snmp-agent local-engineid 800007DB03000BC0005E0B                                                                                    
snmp-agent sys-info version v2c v3                                                                                                  
snmp-agent target-host trap address udp-domain 10.1.1.1 params securityname cipher %^%#Ey)G6^#X.6{X|aE9BbKSSI0WC7l/0>o/ueKU7;SV%^%# 
snmp-agent trap enable feature-name IFNET trap-name linkDown                                                                        
snmp-agent trap enable feature-name IFNET trap-name linkUp  
#
return