S600-E V200R013C00 Web-based Configuration Guide

This document describes how to configure and maintain devices through the web NMS client, including device status statistics, SVF, interface, Ethernet switching, IP service, IP routing, security, ACL, AAA, system management, QoS, diagnosis service, and EasyDeploy.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Logging In to the Device Through the Web System for the First Time

Logging In to the Device Through the Web System for the First Time

Context

When you need to configure a device with the factory settings and do not carry console communication cables or the PC does not have an available serial interface, log in to the device through the web system for the first time and configure the device. After the login, users can conveniently configure the login mode (Web system, Telnet, or STelnet). After the login mode is configured, users can log in to the device using the Web system, Telnet, or STelnet for device maintenance.

You can press and hold down the MODE button to log in to the device through the web system for the first time.

NOTE:

Devices without the MODE button do not support first login through the web system.

First login through the web system, SVF, and EasyDeploy cannot be used together.

Pre-configuration Tasks

Before logging in to a device through the web system, complete the following tasks:

  • Power on the device.
  • Ensure that the device has only the factory settings.

Default Configuration

Table 2-2  Default configurations
Parameter Default Setting
User name admin
Password admin@huawei.com
User level 15
Login IP address 192.168.1.253

Procedure

  1. Connect a PC to the device.

    Connect the PC to any Ethernet interface of the device using network cables.

    NOTE:

    Users can log in to a device for the first time using the web system only when the device is in factory default state. In this case, do not log in to the device through the console interface, because any operation on the console interface leads to the failure of the first login using the web system.

  2. Enter the initial configuration state.

    Before performing this step, ensure that the device uses factory settings and the console interface is not connected.

    Press and hold down the MODE button for 6 seconds or longer. When all indicators are steady green, the device enters the initial configuration state.

    The system sets the switch IP address to 192.168.1.253/24 and the user level to 15 by default.

    NOTE:
    • If the device has been configured when users press and hold down the MODE button for 6 seconds or longer, all indicators blink green fast. In this case, the device is restored to the normal state after 10 seconds, without impact on existing configuration.
    • If the device in the factory settings has just started or has been configured through the console interface when users press and hold down the MODE button for 6 seconds, the device may fail to enter the initial configuration state. When all indicators blink fast for 10s, the device restores to the factory default state.
    • The device automatically exits the initial configuration state and restores the factory settings if users have not saved the settings after 10 minutes.

  3. Configure an IP address for the PC.

    To ensure that the PC and device have reachable routes to each other, configure an IP address on the same network segment with the device IP address for the PC.

  4. Log in to the device through the web system.

    Open the web browser on the PC, enter https://192.168.1.253 in the address bar, press Enter, and then the web system login page is displayed, as shown in Figure 2-1. Enter admin and admin@huawei.com for the default user name and default password, and select the language of the web system. Click GO or directly press Enter. The web system configuration page is displayed.

    Figure 2-1  First login page in the web system
    NOTE:

    The login to the device through the Web system requires that the browser on the PC must be Microsoft Edge, Internet Explorer 10.0, Internet Explorer 11.0, Firefox 58.0 to Firefox 62.0, or Chrome 60.0 to Chrome 69.0. If the browser version or browser patch version is not within the preceding ranges, the web page may not be properly displayed. Upgrade the browser and browser patch.

  5. Configure the device.

    As shown in Figure 2-2, the Web system configuration page allows users to perform the basic and optional configurations. Table 2-3 describes parameters for the basic configuration. After the basic configuration is complete, users can log in to the device through the Web system. Table 2-4 describes parameters for the optional configuration. After the optional configuration is complete, users can log in to the device through Telnet or STelnet.

    A login user can create users for logging in to the device through Telnet or STelnet. The parameter Create User is valid only when Telnet Server or Stelnet Server is On.

    Figure 2-2  Web system configuration page
    Table 2-3  Basic configuration
    Item Description
    Management IP Address Indicates the management IP address of the device. The value is in dotted decimal notation.
    Mask Indicates the mask of the IP address. Select a subnet mask from the drop-down list box.
    Old Password Indicates the default Web login password. This parameter is mandatory.
    WEB User Password

    Indicates the new Web login password. This parameter is mandatory.

    A secure password should contain at least two types of the following: lowercase letters, uppercase letters, numerals, special characters (such as ! $ # %). In addition, the password cannot contain spaces or single quotation marks (').

    Confirm Password

    Confirms the new Web login password. This parameter is mandatory.

    The format is the same as that of WEB User Password.

    WEB User Level

    Indicates the Web user level. Select a user level from the drop-down list box. This parameter is optional.

    Only level 3 users and higher are administrators with management rights. Level 2 users and below are monitoring users. Administrator users have all operation rights of a web page, and monitoring users can only perform ping and tracert operations.

    Table 2-4  Optional configuration
    Item Description
    Device Name

    Specifies the device name.

    The device name cannot contain question marks (?) and cannot start with spaces.

    Telnet Server

    Sets the Telnet function: Enable or disable the Telnet function.

    Stelnet Server

    Sets the STelnet function: Enable or disable the STelnet function.

    User Name

    Specifies the Telnet or STelnet login user name.

    The user name cannot contain / : * ? " < > | ' or %, and cannot start with @.

    Password

    Specifies the password.

    A secure password should contain at least two types of the following: lowercase letters, uppercase letters, numerals, special characters (such as ! $ # %). In addition, the password cannot contain spaces or single quotation marks (').

    Confirm Password

    Confirms the password.

    The format is the same as that of Password.

    User Level

    Indicates the Telnet or STelnet user level. Select a user level from the drop-down list box.

    Only level 3 users and higher are administrators with management rights. Level 2 users and below are monitoring users. Administrator users have all operation rights of a web page, and monitoring users can only perform ping and tracert operations.

  6. Save configuration.

    Click Apply. The configuration is saved. When logging out of the Web system for the first time, the following situations may occur based on the configured management IP address:

    • When the management IP address is on the same network segment as 192.168.1.253/24, the Web system login page is displayed.
    • When the management IP address is not on the same network segment as 192.168.1.253/24, users cannot log in to device through the Web system. In this case, configure an IP address on the same network segment as the management IP address for the PC so that the PC and device have reachable routes to each other.

    Users can log in to the device through the Web system, Telnet, or STelnet for device maintenance.