No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CloudBackup Feature Guide

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado3000 V3, Dorado5000 V3, Dorado6000 V3, and Dorado18000 V3. It describes the implementation principles and application scenarios of the CloudBackup feature, and explains how to configure and manage CloudBackup.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Viewing Performance Information

Viewing Performance Information

This operation allows you to view the real-time backup bandwidth for diagnosis or tuning.

Procedure

  1. Choose Data Protection > CloudBackup > Basic Settings > Performance Throttling.
  2. View the performance information. Table 3-10 describes the parameters.

    NOTE:

    GUIs may vary with product versions and models. The actual GUIs prevail.

    Table 3-10 Performance parameters

    Parameter

    Description

    Value

    Upstream Rate Threshold (MB/s)

    Maximum backup rate and backup data transmission rate allowed by the system.

    [Value range]

    5 MB/s to 999 MB/s

    [Default value]

    The default value varies with product model and version. Check the GUI for the actual value.

    Downstream Rate Threshold (MB/s)

    Maximum restoration rate and restoration data transmission rate allowed by the system.

    [Value range]

    5 MB/s to 999 MB/s

    [Default value]

    The default value varies with product model and version. Check the GUI for the actual value.

    Node Name

    Name of the controller.

    [Example]

    CTE0.A

    ID

    ID of the controller.

    [Example]

    1

    Backup Storage Upstream Rate

    Real-time backup data transmission rate of the current controller.

    [Value range]

    This value is smaller than or equal to the Upstream Rate Threshold (MB/s).

    Backup Storage Downstream Rate

    Real-time restoration data transmission rate of the current controller.

    [Value range]

    This value is smaller than or equal to the Downstream Rate Threshold (MB/s).

    Production Storage Upstream Rate

    Real-time backup rate of the current controller.

    [Value range]

    This value is smaller than or equal to the Upstream Rate Threshold (MB/s).

    Production Storage Downstream Rate

    Real-time restoration rate of the current controller.

    [Value range]

    This value is smaller than or equal to the Downstream Rate Threshold (MB/s).

    NOTE:

    ID, Backup Storage Upstream Rate, Backup Storage Downstream Rate, Production Storage Upstream Rate, and Production Storage Downstream Rate apply to V300R002C10 and later versions.

Download
Updated: 2019-07-17

Document ID: EDOC1100067320

Views: 7623

Downloads: 25

Average rating:
This Document Applies to these Products
Related Version
Related Documents
Share
Previous Next