Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change infoequalizer node

change infoequalizer node

Function

The change infoequalizer node command is used to modify the information of a node in a protocol cluster.

Format

change infoequalizer node < id> [runningStatus=?] [zone_id=?] [external_IP=?] [description=?]

Parameters

Parameter

Description

Value

id ID of a node in a protocol cluster.

The value contains <node_id>_<zone_name> with node_id using 1 to 127 digits and zone_name string using alphanumeric, _(underscore), .(dot) , or -(hyphen)(length is from 3 to 80).The first zone_name character must be alphabet, and the last zone_name character can not be .-_.., press Ctrl+A to view available list.

runningStatus Running status of a node in a protocol cluster.

enabled: A node in a protocol cluster is enabled.

disabled: A node in a protocol cluster is disabled.

external_IP Static IP address of a node in a protocol cluster.

address array string, input most 4 IPs like 192.168.0.1,...192.168.0.4.

description Description.

description string (length is from 1 to 255). Please use '\s' for blank, '\q' for '?' and '\|' for '|'.

Level

Device administrator

Usage Guidelines

The following parameter sets are mutually exclusive. When input any parameter of a set, the parameters of other sets can not be inputed.

{runningStatus},{external_IP}

The following parameter sets are mutually exclusive. When input any parameter of a set, the parameters of other sets can not be inputed.

{runningStatus},{description}.

Example

Modify the information of a node in a protocol cluster.

admin:/>change infoequalizer node 5641_zone6 runningStatus=enabled
Command executed successfully.

System Response

None

Translation