Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show upgrade disk_result

show upgrade disk_result

Function

The show upgrade disk_result command is used to query the result of disk firmware upgrade.

Format

show upgrade disk_result <node_id=?> [slot_id=?]

Parameters

Parameter

Description

Value

node_id Node ID.

The value contains 1 to 127 characters, including letter, digits, hyphens (-), underscores (_), and periods (.).

slot_id Disk slot ID.

The disk slot IDs of the C72 node are different from those of other nodes. The disk slot IDs of the C72 node are combinations of letters A to E and numbers 0 to 14, for example, A01 and B10. The disk slot IDs of other nodes range from 00 to 71.

Level

Read-only user

Usage Guidelines

  • Run the "show upgrade disk_result <node_id>" command to query the firmware upgrade result of disks on a node.
  • Run the "show upgrade disk_result <node_id> [slot_id]" command to query the firmware upgrade result of a disk.

Example

Query the result of disk firmware upgrade.

admin:/>show upgrade disk_result 1883
 
  NodeId SlotId Result     StartTime         StopTime          OldVer NewVer
  ------ ------ ---------- ----------------- ----------------- ------ ------
  1883   0      6          03/11/15 03:51:40 03/11/15 03:51:40 0001   0002

System Response

The following table describes the parameter meanings.

Parameter

Meaning

NodeID

Node ID.

SlotID

Disk slot ID.

Result

Disk firmware upgrade result.

StartTime

Time when disk firmware upgrade starts.

StopTime

Time when disk firmware upgrade ends.

OldVer

Source version of disk firmware upgrade.

NewVer

Target version of disk firmware upgrade.