Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
add notification receiver

add notification receiver

Function

The add notification receiver command is used to add new addresses for receiving alarms, including email addresses and mobile phone numbers.

Format

add notification receiver < alarm_level > [ email_receiver_list=? ] [ message_receiver_list=? ]

Parameters

Parameter

Description

Value

alarm_level Alarm severity.
  • critical
  • major
  • warning
  • info.
email_receiver_list Email address for receiving alarms.

The email address contains 5 to 255 characters and is in the format of user name@domain name. The user name must comply with the following rules: The user name must start and end with a letter, digit, or underscore (_) and can contain hyphens (-), pluses (+), and periods (.), none of which can appear consecutively. The domain name must comply with the following rules: The domain name is in the format of A.B. A and B must start and end with a letter, digit, or underscore (_) and can contain hyphens (-) and periods (.), none of which can appear consecutively. Separate multiple domain names from each other using periods (.). Receiver's E-mail list separated by comma.

"email_receiver_list" or "message_receiver_list" must be used at least one.

message_receiver_list Mobile phone number for receiving alarms.

Mobile phone numbers are listed as follows: phone number 1, phone number 2.

The mobile phone numbers are separated by semicolons (,) from one another.

A mobile phone number consists of a plus (+) and 2 to 30 digits or 3 to 31 digits.If a plus (+) is entered, you must add the country code before the mobile phone number, for example, +8613010811500, otherwise, the mobile phone number cannot receive short messages.

"message_receiver_list" or "email_receiver_list" must be used at least one.

Level

Administrator

Usage Guidelines

None

Example

Add new addresses for receiving alarms.

admin:/>add notification receiver info email_receiver_list=111@hotmail.com message_receiver_list=123456789
add email receiver(111@hotmail.com) succeeded.
add message receiver(123456789) succeeded.

System Response