Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show optical_transceiver status

show optical_transceiver status

Function

The show optical_transceiver status command is used to query optical module status information.

Format

show optical_transceiver status [ id=? ] [ node_id=? ] [ parent_type=? ]

Parameters

Parameter

Description

Value

id Optical module ID.

The value can contain only 1 to 127 letters, digits, hyphens (-), underscores (_), and periods (.).

node_id Node ID.

The value can contain only 1 to 127 letters, digits, hyphens (-), underscores (_), and periods (.).

parent_type Node type.

The value is snas_node, indicating a storage system node.

Level

Device administrator

Usage Guidelines

  • Run the show optical_transceiver status [id=?] [node_id=?] [parent_type=?] command to query the status information of a specified optical module.
  • Run the show optical_transceiver status command to query the status information of all optical modules in the system.
  • Read-only users can also run this command to view information.

Example

Query optical module status information.

admin:/>show optical_transceiver status 
 
  ID     parentType  nodeID  healthStatus  runningStatus  location  sfpmodetype  speed   vendor 
  -------  ----------  ------  ------------  -------------  --------  -----------  ------  ------- 
  23558.0  snas_node   23558   Fault         Normal         1         1            1       TIME   
  23558.1  snas_node   23558   Fault         Normal         2         1            1       TIME   
 
model       sn              portname  devname   
----------  --------------  --------  -------- 
D09181-1A   D131870077      eth4      F41-N206 
D09181-1A   D131830266      eth5      F41-N206

System Response

The following table describes the parameter meanings.

Parameter

Meaning

ID

Optical module ID.

parentType

Node type.

nodeID

Node ID.

healthStatus

Health status.

runningStatus

Running status.

location

Location.

sfpmodetype

Working mode.

speed

Speed.

vendor

Vendor.

model

Model.

sn

Optical module SN.

portname

Network port name.

devname

Device name.