Overview
Description | Part Number | Model | First Supported Version | Remarks |
---|---|---|---|---|
USG6565E AC Host (2*GE WAN+8*GE Combo+2*10GE SFP+,1 AC power) | 02353AEJ | USG6565E-AC | V600R007C00 | - |
USG6565E AC Host(2*GE WAN+8*GE Combo+2*10GE SFP+,1 AC power) | 02353AEJ-001 | USG6565E-AC | V600R007C20SPC500 | - |
Appearance
Components
1. Product series ID |
2. Indicator and button area |
3. Fixed interface area |
4. Protective ground terminal |
5. MAC label |
6. SN label |
7. Fan module |
8. Optional power module slot |
9. Power module |
- |
Name |
Description |
---|---|
Product series ID |
Indicates the product series of the device. For details about the product model, see the nameplate in the lower part of the device. |
Indicator and button area |
Provides multiple indicators to display the running status of the device in real time and provides the RST button for emergency maintenance. |
Fixed interface area |
Provides service ports, USB ports, console ports, and out-of-band management ports for device configuration and maintenance. |
Protective ground terminal |
Connects the M4 OT terminal of a PGND cable to the cabinet or the ground bar in the equipment room. |
MAC label |
Uniquely identifies the MAC address of the device, which is required during network forwarding configuration. |
SN label |
Uniquely identifies the device, which needs to be provided for the local technical support personnel to apply for a license. |
Fan module |
Dissipates heat for the device and is swappable. The fan module can be removed for no more than 1 minute. |
Power module |
Provides power input and distribution for the device. One power module is included in the standard configuration. Two power modules can be configured to achieve 1+1 power redundancy. When one power module is running properly, the other one is hot swappable. |
Indicators and Buttons
1. PWR, SYS, USB, HA, WAN and CLOUD indicators |
2. GE electrical port ACT indicator |
3. GE electrical port LINK indicator |
4. Optical port ACT indicator |
5. Optical port LINK indicator |
6. MGMT port indicator |
7. RST button |
- |
- |
- |
Arrowheads of optical ports show the positions of the ports. A down arrowhead indicates a port in the upper part, and an up arrowhead indicates a port in the lower part.
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
PWR | Power indicator | Green | Steady on | The power module works properly. |
- | Off | The power module is faulty or the power cable is disconnected. | ||
SYS | System indicator | Green | Steady on | The system is being powered on or restarted. |
Green | Blink every two seconds (0.5 Hz) | The system is running normally. | ||
Green | Blink four every second (4 Hz) | The system is starting. | ||
Red | Steady on |
NOTE:
If the system starts with dual power modules but one power module is not powered on, the System indicator is steady red, but the system is operating properly. |
||
- | Off | The system is not running. | ||
USB | USB indicator | Green | Steady on | USB-based deployment is complete. |
Green | Blink four every second (4 Hz) | The data of USB-based deployment is being read. | ||
Red | Steady on | USB-based deployment fails. | ||
- | Off | If USB-based deployment is disabled, the system is in the default state. | ||
HA | HA indicator | Green | Steady on | Management master device in hot standby. |
Green | Blink every two seconds (0.5 Hz) | Management backup device in hot standby. | ||
Red | Steady on | Hot standby is faulty. | ||
- | Off | The hot standby function is disabled. | ||
WAN | WAN indicator | - | Off | Reserved. |
CLOUD | CLOUD indicator | Green | Steady on | Connected to the cloud management platform. |
Green | Blink four every second (4 Hz) | Connecting to the cloud management platform, transmitting or receiving data. | ||
- | Off | Not connected or registered to the cloud management platform. | ||
- | ACT indicator for GE Ethernet electrical ports | Yellow | Blink (12 Hz) | Data is being sent or received through the port. |
- | Off | No data is being sent or received through the port. | ||
- | LINK indicator for GE Ethernet electrical ports | Green | Steady on | The link of the port is connected. |
- | Off | The link of the port is disconnected. | ||
- | ACT indicator for optical ports | Yellow | Blink (12 Hz) | Data is being sent or received through the port. |
- | Off | No data is being sent or received through the port. | ||
- | LINK indicator for optical ports | Green | Steady on | The link of the port is connected. |
- | Off | The link of the port is disconnected. | ||
- | Indicator for MGMT port | Green | Steady on | The link of the port is connected. |
Green | Blink | Data is being sent or received through the port. | ||
- | Off | The link of the port is disconnected. |
Silkscreen | Name | Description |
---|---|---|
RST | RST button | To restart the device, press the RST button. Ensure that the running configuration is saved before pressing the RST button. This button can enable you to restore the default settings with one click. To be specific, you can hold down the RST button for 5 seconds and then release it to restore the default settings and restart the device. |
Ports
1. Combo port |
2. 10GE optical port |
3. WAN port |
4. SSD card slot |
5. USB 3.0 port |
6 USB 2.0 port |
7. Console port |
8. MGMT port |
- |
- |
Port | Connector Type | Description | Available Components |
---|---|---|---|
Combo ports (0 to 7) | RJ45 + SFP | Combo ports. Combo ports are logic ports. One combo port can work as a GE electrical interface or a GE optical port. Each combo port has only one internal forwarding port. When the electrical port is enabled, the optical port is disabled. When the optical port is enabled, the electrical port is disabled. The electrical and optical ports of a combo port use the same interface view, numbered from GigabitEthernet 0/0/0 to GigabitEthernet 0/0/7. By default, the combo port is used as an electrical port. You can use the combo enable { copper | fiber } command to set the working mode of combo ports according to network requirements. NOTE:
Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. |
NOTE:
In V600R007C20SPC500 and later versions, Combo ports support 100Mbps SFP Optical Modules. |
10GE optical ports (0 to 1) | SFP+ | 2 10GE optical ports, numbered from XGigabitEthernet 0/0/0 to XGigabitEthernet 0/0/1. NOTE:
In V600R007C20 and later versions, 10GE optical ports support 1Gbps SFP Copper Modules and 1Gbps eSFP Optical Modules. By default, the rate of 10GE optical ports are 10GE. You can run the set device port-config-mode [ 10ge | ge ] command to set the rate of 10GE optical ports are to 10GE or GE as required. |
|
WAN ports (0 to 1) | RJ45 | 2 10/100/1000M autosensing Ethernet electrical ports, numbered from WAN 0/0/0 to WAN 0/0/1. The device is connected to the WAN or cloud management center using a network cable. |
|
SSD card slot | - | The M.2 module is inserted to record logs and reports in real time. The M.2 module is optional. You can purchase the M.2 module as required. | |
USB 3.0 port | USB 3.0 Type A | USB ports allow you to insert USB devices for system software upgrades. For details on upgrades through USB devices, refer to the Upgrade Guide delivered with the device. |
|
USB 2.0 port | USB 2.0 Type A | USB ports allow you to insert USB devices for system software upgrades. For details on upgrades through USB devices, refer to the Upgrade Guide delivered with the device. | USB flash drive that complies with USB 2.0 |
Console port | RJ45 | Console ports allow you to locally connect a PC to the device. You can use a console cable to connect the console port (RJ45) on the device to the COM port on your PC and use a serial port terminal program on your PC to access, configure, and manage the device. |
|
MGMT port | RJ45 | Out-of-band 10/100/1000M RJ45 autosensing Ethernet management port. The interface number is METH 0/0/0 and the default IP address of the interface is 192.168.0.1. You can connect this port to the network port or any reachable port on a PC through a network cable. Then, you can use Telnet to access the CLI or use a web browser to access the web UI to configure, manage, and maintain the device. NOTE:
The MGMT port cannot be used as a service port. |
Power Supply System
The power supply system has one PAC60S12-AR, PAC60S12-R, or PAC600S12-CB AC power module. Two power modules can be configured for 1+1 power redundancy.
Heat Dissipation System
The heat dissipation system uses one FAN-023A-B module to dissipate heat for the system. From the front panel, the device provides a front-to-rear air flow. The fan module locates at the air exhaust of the system.
Technical Specifications
Item | Specification |
---|---|
Installation Type |
|
Cabinet installation standard | Cabinet with a depth of 600 mm or above |
Dimensions without packaging (H x W x D) [mm(in.)] | 43.6 mm x 442 mm x 420 mm (1.72 in. x 17.4 in. x 16.54 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 220 mm x 550 mm x 530 mm (8.66 in. x 21.65 in. x 20.87 in.) |
Chassis height [U] | 1 U |
Weight with packaging [kg(lb)] |
|
Weight without packaging [kg(lb)] |
|
CPU | 1 CPU, 4 cores/CPU, up to 1.4 GHz |
Memory | DDR4 4 GB |
NOR Flash | 32 MB NOTE:
The specification of the NOR flash of the device to be delivered is 64 MB. You can run the display version command to view the NOR flash memory specification of a device. |
NAND Flash | 2 GB |
Hard disk | Optional. M.2 SSD (240GB), hot-swappable. |
Console port | RJ45 |
Eth Management port | RJ45 |
Maximum power consumption [W] |
|
Maximum heat dissipation [BTU/hour] |
|
MTBF [year] | 68.98 year |
MTTR [hour] | 2 hour |
Power supply mode | AC built-in |
Number of power modules | 1 |
Rated input voltage [V] | 100 V to 240 V, 50 Hz/60 Hz |
Input voltage range [V] | 90 V to 290 V, 47 Hz to 63 Hz |
Types of fans | Pluggable |
Number of fan modules | 1 |
Heat dissipation mode | The fan module locates at the air exhaust of the system. |
Airflow direction | Air inlet from front and air outlet from rear |
Maximum number of 10GE ports | 2 |
Maximum number of GE ports | 8 |
Maximum number of electrical ports | 8 |
Redundant power supply | Two power modules are supported for 1+1 power redundancy. |
Long-term operating temperature [°C(°F)] | 0°C to 45°C |
Storage temperature [°C(°F)] | -40°C to 70°C |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | 0 m to 5000 m |
Storage altitude [m(ft.)] | 0 m to 5000 m |
- The width does not include the size of mounting ears.
- The height is 1U (1U = 1.75 inches, or about 44.45 mm), which is a height unit defined in International Electrotechnical Commission (IEC) 60297 standards.
- Temperature and humidity are measured 1.5 m above the floor and 0.4 m in front of the rack when no protection plate exists before or after the rack.