USG6625E
Overview
Description | Part Number | Model | First supported version |
---|---|---|---|
USG6625E AC Host (16*GE RJ45 + 6*GE SFP + 6*10GE SFP+,16G Memory,1 AC POWER) | 02352RQN | USG6625E-AC | V600R007C00 |
Appearance
Components
1. Product series ID |
2. Indicator and button area |
3. HDD/SSD slot |
4. Fixed interface area |
5. Protective ground terminal |
6. MAC label |
7. SN label |
8. Fan module |
9. Optional power module slot |
10. Power module |
Name |
Description |
---|---|
Product series ID |
Indicates the product series of the device. For details about the product model, see the nameplate in the lower part of the device. |
Indicator and button area |
Provides multiple indicators to display the running status of the device in real time and provides the RST button for emergency maintenance. |
HDD/SSD slot |
Houses hard disks for storing log and report data. |
Fixed interface area |
Provides service ports, USB ports, console ports, and out-of-band management ports for device configuration and maintenance. |
Protective ground terminal |
Connects the M4 OT terminal of a PGND cable to the cabinet or the ground bar in the equipment room. |
MAC label |
Uniquely identifies the MAC address of the device, which is required during network forwarding configuration. |
SN label |
Uniquely identifies the device, which needs to be provided for the local technical support personnel to apply for a license. |
Fan module |
Dissipates heat for the device and is swappable. The fan module can be removed for no more than 1 minute. The silkscreens of the fan module slots are FAN1 to FAN3, and the corresponding slot numbers are 4, 5, and 6 respectively. |
Power module |
Provides power input and distribution for the device. One power module is included in the standard configuration. Two power modules can be configured to achieve 1+1 power redundancy. When one power module is running properly, the other one is hot swappable. The silkscreens of the power module slots are PWR1 and PWR2, and the corresponding slot numbers are 2 and 3 respectively. |
Indicators and Buttons
1. PWR, SYS, USB, HA, WAN and CLOUD indicators |
2. OFL indicator |
3. GE electrical port ACT indicator |
4. GE electrical port LINK indicator |
5. Optical port ACT indicator |
6. Optical port LINK indicator |
7. MGMT port indicator |
8. RST button |
9. OFL button |
- |
Arrowheads of optical ports show the positions of the ports. A down arrowhead indicates a port in the upper part, and an up arrowhead indicates a port in the lower part.
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
PWR | Power indicator | Green | Steady on | The power module is working properly. |
- | Off | The power module is faulty or the device is not powered on. | ||
SYS | SYS indicator | Green | Steady on | The system is being powered on or restarted. |
Green | Blinks once every 2 seconds (0.5 Hz). | The system is running normally. | ||
Green | Blinking four times every second (4 Hz) | The system is starting. | ||
Red | Steady on |
NOTE:
If the system starts with two power modules and one power module is not powered on, the SYS indicator is steady red, but the system is running properly. |
||
- | Off | The system is not running. | ||
USB | USB indicator | Green | Steady on | USB-based deployment has been completed. |
Green | Blinking four times every second (4 Hz) | The system is reading data from the USB flash drive. | ||
Red | Steady on | USB-based deployment fails. | ||
- | Off | USB-based deployment is disabled (default state). | ||
HA | HA indicator | Green | Steady on | Management master device in hot standby or clusterdeployment. |
Green | Blinks once every 2 seconds (0.5 Hz). | Management backup device in hot standby or cluster deployment. | ||
Red | Steady on | Hot standby or the cluster is faulty. | ||
- | Off | The hot standby or the cluster function is disabled. | ||
WAN | WAN indicator | - | Off | Reserved function. This function is not enabled. |
CLOUD | CLOUD indicator | Green | Steady on | Connected to the cloud management platform. |
Green | Blinking four times every second (4 Hz) | Connecting to the cloud management platform, transmitting or receiving data. | ||
- | Off | The device is not connected to the cloud management platform. | ||
- | OFL indicator | Green | Steady on | The hard disk can be removed. |
- | Off | The hard disk cannot be removed. | ||
- | ACT indicator of the GE electrical port | Yellow | Blinking (12 Hz) | The port is sending or receiving data. |
- | Off | The port is not sending or receiving data. | ||
- | LINK indicator of the GE electrical ports | Green | Steady on | The port link is connected. |
- | Off | No link is established on the port. | ||
- | LINK indicator of the optical port | Yellow | Blinking (12 Hz) | The port is sending or receiving data. |
- | Off | The port is not sending or receiving data. | ||
- | LINK indicator of an optical port | Green | Steady on | The port link is connected. |
- | Off | No link is established on the port. | ||
- | MGMT port indicator | Green | Steady on | The port link is connected. |
Green | Blinking (12 Hz) | The port is sending or receiving data. | ||
- | Off | No link is established on the port. |
Silkscreen | Name | Description |
---|---|---|
RST | RST button | To restart the device, press the RST button. Ensure that the running configuration is saved before pressing the RST button. This button can enable you to restore the default settings with one click. To be specific, you can hold down the RST button for 5 seconds and then release it to restore the default settings and restart the device. |
OFL | OFL button | To remove a hard disk, press and hold the OFL button for four seconds until the OFL indicator turns on. |
Ports
1. HDD/SSD slot |
2. GE electrical port |
3. GE optical port |
4. 10GE optical port |
5. USB 2.0 port |
6. Console port |
7. MGMT port |
- |
- |
- |
Port | Connector Type | Description | Available Components |
---|---|---|---|
HDD/SSD Hard disk slot | - | The hard disks are optional. You can purchase hard disk from Huawei if needed. |
NOTE:
|
GE electrical ports (0 to 15) | RJ45 | 16 10/100/1000M autosensing Ethernet electrical ports, numbered from GigabitEthernet 0/0/0 to GigabitEthernet 0/0/15. NOTE:
Arrowheads show the positions of ports. A down arrowhead indicates a port at the bottom, and an up arrowhead indicates a port at the top. |
|
GE optical ports (16 to 21) | SFP | 6 GE autosensing Ethernet optical ports, numbered from GigabitEthernet0/0/16 to GigabitEthernet0/0/21. | |
10GE optical ports (0 to 5) | SFP+ | 6 GE/10GE autosensing Ethernet optical ports, numbered from XGigabitEthernet0/0/0 to XGigabitEthernet0/0/5. | |
USB 2.0 port | USB 2.0 Type A | USB ports allow you to insert USB devices for system software upgrades. For details on upgrades through USB devices, refer to the Upgrade Guide delivered with the device. | USB flash drive |
Console port | RJ45 | Console ports allow you to locally connect a PC to the device. You can use a console cable to connect the console port (RJ45) on the device to the COM port on your PC and use a serial port terminal program on your PC to access, configure, and manage the device. |
|
MGMT port | RJ45 | Out-of-band 10/100/1000M RJ45 autosensing Ethernet management port. The interface number is METH 0/0/0 and the default IP address of the interface is 192.168.0.1. You can connect this port to the network port or any reachable port on a PC through a network cable. Then, you can use Telnet to access the CLI or use a web browser to access the web UI to configure, manage, and maintain the device. NOTE:
The MGMT port cannot be used as a service port. |
Power Supply System
The power supply system has one PAC600S12-CB, PAC600S12-DB, or PAC600S12-EB AC power module, but two power modules can be configured for 1+1 power redundancy.
Heat Dissipation System
The heat dissipation system consists of three FAN-023A-B modules working in 2+1 backup mode. From the front panel, the device provides a front-to-rear air flow. The fan module locates at the air exhaust of the system.
Technical Specifications
Item | Specification |
---|---|
Installation Type | Rack |
Cabinet installation standard | Cabinet with a depth of 600 mm or above |
Dimensions without packaging (H x W x D) [mm(in.)] | 43.6 mm x 442 mm x 420 mm (1.72 in. x 17.4 in. x 16.54 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] | 225 mm x 550 mm x 530 mm (8.86 in. x 21.65 in. x 20.87 in.) |
Chassis height [U] | 1 U |
Weight with packaging [kg(lb)] | 10.9 kg (24.03 lb) |
Weight without packaging [kg(lb)] | 7.75 kg (17.09 lb) |
CPU | 1 CPU, 16 cores/CPU, up to 1.85 GHz |
Memory | DDR4 8 GB x 2 |
NOR Flash | 64MB |
NAND Flash | 2 GB |
Hard disk | Optional. You can purchase a 2.5-inch SATA hard disk (240 GB/960 GB/1000 GB) from Huawei based on the site requirements. The hard disk is hot swappable. |
Console port | RJ45 |
Eth Management port | RJ45 |
Maximum power consumption [W] | 118 W |
Maximum heat dissipation [BTU/hour] | 403.56 BTU/hour |
MTBF [years] | 37.76 years |
MTTR [hours] | 2 hours |
Power supply mode | AC built-in |
Number of power modules | 1 |
Rated input voltage [V] | 100 V to 240 V, 50 Hz/60 Hz |
Input voltage range [V] | 90 V to 290 V, 47 Hz to 63 Hz |
Maximum input current [A] | 8 A |
Maximum output power [W] | 600 W |
Types of fans | Pluggable |
Number of fan modules | 3 |
Heat dissipation mode | The fan module locates at the air exhaust of the system. |
Airflow direction | Air inlet from front and air outlet from rear |
Maximum number of 10GE ports | 6 |
Maximum number of GE ports | 6 |
Maximum number of electrical ports | 16 |
Redundant power supply | Two power modules are supported for 1+1 power redundancy. |
Redundant fans | 2+1 |
Long-term operating temperature [°C(°F)] |
|
Storage temperature [°C(°F)] | -40°C to 70°C |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] |
|
Storage altitude [m(ft.)] | 0 m to 5000 m |
- The width does not include the size of mounting ears.
- The height is 1U (1U = 1.75 inches, or about 44.45 mm), which is a height unit defined in International Electrotechnical Commission (IEC) 60297 standards.
- Temperature and humidity are measured 1.5 m above the floor and 0.4 m in front of the rack when no protection plate exists before or after the rack.
- The operating temperature change rate of a device with HDDs must be less than or equal to 20°C/hour.