Mounting a Device to a Specified Location
The USG6510E, USG6510E-POE, USG6530E can be mounted in a 19-inch standard cabinet. When no cabinet is available, install the USG6510E, USG6510E-POE, USG6530E on a workbench or a wall.
Mounting a Device in a Cabinet
The USG6510E, USG6510E-POE, USG6530E can be mounted in a 19-inch standard cabinet using mounting ears.
Precautions
Before installing the USG, check the following items:
- Before unpacking the carton, ensure that the packing carton is intact and not damaged or soaked. Stop unpacking if the USG is rusted or soggy. Then, investigate causes and contact the supplier.
- The cabinet is stable.
- The position for the USG in the cabinet is well arranged.
- Ensure that the USG is 1 U of clearance from any devices above and below and 150 mm of clearance from any devices on the right or left.
- The device to be installed is staged near the cabinet for convenience.
You can place either end of the USG chassis towards the front door of the cabinet. In this manual, the front panel of the USG is towards the front door of the cabinet.
Tools and Accessories
- Phillips screwdriver
- Floating nuts and matching screws
- Floating mounting bar
- Mounting ears and matching screw (purchased separately, BOM numbers: 21240477)
- Holding plate and matching screw (purchased separately, BOM numbers: 21243646)
Procedure
- Install mounting ears on the chassis.
Use a Phillips screwdriver to fix the mounting ears to both sides of the chassis with M4 screws, as shown in Figure 5-2.
If the tray installation mode is used, skip this step.
- Install floating nuts.
Figure 5-3 illustrates the positions of floating nuts.
Use M6 screws to fix the floating nuts at the positions specified in Figure 5-3, as shown in Figure 5-4.
- (Optional) Install the device to a tray. For details, see the installation guide delivered with the tray.
- Mount the USG in the cabinet.
Mounting a Device on a Workbench
If you do not have a cabinet, you can mount the USG6510E, USG6510E-POE, USG6530E on a workbench.
Precautions
Before unpacking the carton, ensure that the packing carton is intact and not damaged or soaked. Stop unpacking if the USG is rusted or soggy. Then, investigate causes and contact the supplier.
- Reliably grounded.
- Clean, firm, and securely installed.
Procedure
- Fix the rubber feet to the round notches at the bottom
of the USG.
Install foot pads at the bottom of the USG to ensure smooth contact between the USG and the workbench and avoid friction between the surface of the USG and the workbench.
- Place the USG on the workbench.
Figure 5-6 Placing the USG with rubber feet on a workbench
Mounting a Device Against a Wall
When no cabinet is available, you can mount the USG6510E, USG6510E-POE, USG6530E on a wall. The customer must have expansion screws for wall-mounting.
Precautions
Before unpacking the carton, ensure that the packing carton is intact and not damaged or soaked. Stop unpacking if the USG is rusted or soggy. Then, investigate causes and contact the supplier.
Tools and Accessories
- Ruler
- Marker
- Hammer drill
- Vacuum cleaner
- Hammer
- Phillips screwdriver
- Mounting ears and matching screw (purchased separately, BOM numbers: 21240477)
Procedure
- Fix mounting ears to both sides of the panel with ports using M4 screws.Figure 5-7 Installing the mounting ears on the chassis
- Determine the locations of four mounting holes on the wall using a ruler and mark the mounting holes with a marker.
- The wall must be a bearing wall. Otherwise, the wall is not suitable for wall-mounting.
- Ensure that the height of mounting holes is proper so that the indicators are easy to view.
Figure 5-8 Spacing between mounting holes - Drill holes and install expansion bolts.
Ensure that the expansion bolts are secure and reliable. Otherwise, the tension after cables are connected may cause the USG6510E, USG6510E-POE, USG6530E to fall.
- Secure the USG on the wall and fasten the flat washers, spring washers, and nuts in order.
The USG supports upward mounting and downward mounting. To prevent water from entering into ports and causing device damage, you are advised to mount the USG with ports facing downward.
Figure 5-10 Mounting the USG on a wall