A power adapter can be used to supply power for a USG6510E, USG6510E-POE, USG6530E. Prepare an AC power cable to connect the power connector and the power source of the equipment room.
Context
Before connecting a power connector, ensure that the power source of the equipment room meets the input requirements of the USG power module.
Procedure
- Ensure that the PGND cable is properly grounded.
- Insert a cable-retention clip into the jack next to the power socket.
- Connect a power adapter.
- Plug the C7 plug of the AC power cable into the C14 socket of the power adapter.
- Insert the tuning fork plug connector of the power adapter into the power socket on the USG rear panel and adjust the cable-retention clip to an appropriate position.
- Use a cable-retention clip to bundle the cable of the power adapter and adjust the cable-retention clip to fasten the cable.
- Plug the other end of the AC power cable to the AC power socket or the output of the AC power supply device.
The USG does not have any power switch. The power supply switch determines the power-on and power-off of the USG.
Figure 5-17 Connecting a power adapter to the (USG6510E, USG6530E)![Click to enlarge]()
Figure 5-18 Connecting a power adapter to the (USG6510E-POE)![Click to enlarge]()
Follow-up Procedure
Verify the following after the connection is complete:
- The power cable is firmly connected to the power supply socket.
- If multiple USGs are deployed, the power cables of each USG are correctly labeled for distinction.