Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring the Overhead Byte

Configuring the Overhead Byte

Context

Different device manufactures require different overhead bytes for a POS interface. Ensure that the C2, J0, and J1 overhead bytes of both ends are the same. Otherwise, the two devices cannot be connected.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface pos interface-number

    The POS interface view is displayed.

  3. Run
    • flag c2 c2–value
    • flag j0 { 1byte-mode value | 16byte-mode value | 64byte-mode value }
    • flag j1 { 1byte-mode value | 16byte-mode value | 64byte-mode value }

    The default overhead bytes for the SDH are used: The C2 overhead byte is 0x16, J0 and J1 overhead bytes are blank.