Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Configuring Optical Module Attributes

(Optional) Configuring Optical Module Attributes

Context

After configuring optical module attributes on a PON interface, you can monitor the interface status on the NMS.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface pon interface-number

    The PON interface view is displayed.

  3. Run laser { auto | off | on [ time-value ] }

    The laser working mode of the PON interface optical module is configured.

    The default laser working mode is auto.

  4. Run optical-module threshold bias { lower-limit lower-limit | upper-limit upper-limit }*

    The lower alarm threshold and upper alarm threshold of the bias current are set for the optical module.

    The recommended value of lower-limit is 2.

    The recommended value of upper-limit is 70.

  5. Run optical-module threshold rx-power { lower-limit lower-limit | upper-limit upper-limit }*

    The lower alarm threshold and upper alarm threshold of the receiving optical power are set for the optical module.

    The recommended value of lower-limit is -35.00.

    The recommended value of upper-limit is 1.00.

  6. Run optical-module threshold tx-power { lower-limit lower-limit | upper-limit upper-limit }*

    The lower alarm threshold and upper alarm threshold of the transmitting optical power are set for the optical module.

    The recommended value of lower-limit is -1.00.

    The recommended value of upper-limit is 7.00.

  7. Run optical-module threshold temperature { lower-limit lower-limit | upper-limit upper-limit }*

    The lower alarm threshold and upper alarm threshold of the temperature are set for the optical module.

    The recommended value of lower-limit is -10.

    The recommended value of upper-limit is 100.

  8. Run optical-module threshold voltage { lower-limit lower-limit | upper-limit upper-limit }*

    The lower alarm threshold and upper alarm threshold of the voltage are set for the optical module.

    The recommended value of lower-limit is 2.97.

    The recommended value of upper-limit is 3.63.

Follow-up Procedure

To remove all alarm thresholds that are configured step 4 through step 8, run the undo optical-module threshold command.