No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

CLI-based Configuration Guide - Interface Management

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the basic concepts, configuration procedures, and configuration examples of the interfaces supported by the device.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring a Capability on a G.SHDSL Interface

Configuring a Capability on a G.SHDSL Interface

Prerequisites

The G.SHDSL interface has been deactivated.

Context

To enable the device to connect to the peer device, configure the capability for the G.SHDSL interface card based on the chip type of the peer device. When the peer device uses the g-shdsl mode, you must configure the g-shdsl mode on the device.

Procedure

  • Configure the g-shdsl.bis mode.

    1. Run system-view

      The system view is displayed.

    2. Run either of the following commands to enter the G.SHDSL interface view.

      • If the transmission mode is set to ATM, run:
        interface atm interface-number
      • If the transmission mode is set to PTM, run:
        interface ethernet interface-number
    3. Run shdsl capability { auto | g-shdsl.bis }

      A capability is configured.

      By default, a G.SHDSL interface uses the auto mode.

    4. Run shdsl pam { 16 | 32 | 64 | 128 | auto }

      The modulation mode is configured.

      By default, a G.SHDSL interface uses the auto mode.

      NOTE:

      If a G.SHDSL interface uses the auto mode, only the 16 PAM mode and 32 PAM mode can be configured automatically, the 64 PAM mode and 128 PAM mode must be configured manually.

    5. Run shdsl bind m-pair 2 [ pairs { auto-enhanced | enhanced | standard } ]

      A binding mode is configured.

      By default, a G.SHDSL interface uses the auto-enhanced mode.

      NOTE:

      Only G.SHDSL interfaces in ATM mode support this command.

      This command can only be executed on interface 0 or 2.

    6. Run shdsl rate maximum maximum

      The maximum rate of a G.SHDSL interface is set.

      When the g-shdsl.bis mode is used, the value ranges from 192 to 15296, in kbit/s.

    7. Run shdsl rate minimum minimum

      The minimum rate of a G.SHDSL interface is set.

      When the g-shdsl.bis mode is used, the value ranges from 192 to 15296, in kbit/s.

  • Configure the g-shdsl mode.

    NOTE:

    When the g-shdsl mode is configured, strictly perform the following operations. Otherwise, the link cannot be activated when the local device is connected to the peer device.

    1. Run system-view

      The system view is displayed.

    2. Run either of the following commands to enter the G.SHDSL interface view.

      • If the transmission mode is set to ATM, run:
        interface atm interface-number
      • If the transmission mode is set to PTM, run:
        interface ethernet interface-number
    3. Run shdsl capability g-shdsl

      A capability is configured.

    4. Run shdsl pam 16

      The modulation mode is configured.

      By default, a G.SHDSL interface uses the auto mode.

    5. Run shdsl bind m-pair 2 [ pairs enhanced ]

      A binding mode is configured.

      NOTE:

      Only G.SHDSL interfaces in ATM mode support this command.

      This command can only be executed on interface 0 or 2.

    6. Run shdsl rate maximum maximum

      The maximum rate of a G.SHDSL interface is set.

      When the g-shdsl mode is used, the value must range from 192 to 2304.

    7. Run shdsl rate minimum minimum

      The minimum rate of a G.SHDSL interface is set.

      When the g-shdsl mode is used, the value must range from 192 to 2304.

Translation
Download
Updated: 2019-03-06

Document ID: EDOC1100069331

Views: 20721

Downloads: 89

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next