Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Default Settings for CT1/PRI Interfaces

Default Settings for CT1/PRI Interfaces

This section provides the default settings for a CT1/PRI interface.

Table 6-1  Default settings for a CT1/PRI interface

Parameter

Default Setting

Working mode of the 1E1T1-M/2E1T1-M interface card

e1-data (CE1/PRI mode)

Cable type applicable to the CT1/PRI interface

120 ohm balanced cable (twisted pair)

Attenuation or length of the transmission line matching the CT1/PRI interface

long -7.5db

Clock mode

Slave clock mode

Line idle code type

0x7e

Interframe filling tag type and minimum number of interframe filling tags

Interframe filling tag type: 0x7e; minimum number of interframe filling tags: 4

Frame format

ESF

Whether to invert data

No

Whether to perform RAI detection

Yes

Alarm thresholds

  • Alarm Indication Signal (AIS) alarm threshold: level 1
  • Loss of Frame Alignment (LFA) alarm threshold: level 1
  • Loss of Signal (LOS) alarm threshold: The value of pulse-detection is 176 and the value of pulse-recovery is 22, indicating that a LOS alarm is generated if less than 22 pulses are detected within 176 pulse intervals.