Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Configuring Loopback Detection

Configuring Loopback Detection

Context

  • After the loopback detection is enabled on an interface using the loopback command, the Ethernet interface or link on the interface cannot function properly. When the loopback detection test is complete, run the undo loopback command to disable it immediately.

Loopback detection needs to be enabled for special function testing, for example, Ethernet interface diagnosis. When loopback detection is enabled on an Ethernet interface, the interface works in the full-duplex mode. When loopback detection is disabled, the interface restores to the default configuration.

Table 2-5 describes the loopback detection classification.
Table 2-5  Loopback detection classification

Type

Description

Hardware loopback

Connect the transmit and receive ends with a cable to form a loop so that the device receives the signals sent by itself.

Software loopback

Remote loopback (external loopback)

The local interface does not forward packets received from the remote interface based on their destination addresses. Instead, it sends the packets back to the remote interface.

Local loopback (internal loopback)

Packets sent from an interface are sent back to the local device.

NOTE:

An Ethernet interface does not support remote loopback.

Procedure

  1. Run system-view

    The system view is displayed.

  2. Run interface interface-type interface-number

    The interface view is displayed.

  3. Run loopback internal

    Internal loopback detection is configured on the Ethernet interface.

    By default, loopback detection is disabled on an Ethernet interface.